RDPSEC NIR1 Series Скачать руководство пользователя страница 1

Installation Steps

1.  Mount Illuminator
2.  Connect Illuminator to low voltage  

power supply 

    – Input 12-24V DC/ 24V AC

Optional Set-up (if required)

3.  Adjust Power to alter light intensity
4.  Adjust Photocell sensitivity

 

5.  Photocell following contact and 

Telemetry input

Set Up Steps

1.  Position illuminator adjacent to 

camera and point towards scene 

2.  Adjust vertical and horizontal  

position of lamp to ensure full field  

of view illuminated

3.  Tighten all fixings

Package Contents

1.  Illuminator including mounting 

bracket

Installation Guide

Overview

This installation guide provides instructions for installing the NIR series 

illuminators

PLEASE NOTE

:

Ensure operating voltage is 

correct for unit being installed 

(12-24V DC/ 24V AC)

Version: 1

Содержание NIR1 Series

Страница 1: ...t Up Steps 1 Position illuminator adjacent to camera and point towards scene 2 Adjust vertical and horizontal position of lamp to ensure full field of view illuminated 3 Tighten all fixings Package Contents 1 Illuminator including mounting bracket Installation Guide Overview This installation guide provides instructions for installing the NIR series illuminators PLEASE NOTE Ensure operating voltag...

Страница 2: ...n DC AC Black Wire Red Wire Specifications subject to change without notice Installation to be carried out by suitable trained and qualified personnel Do not continually stare at lamp NIR1 Series NIR2 Series NIR3 Series 1 5m Install in a well ventilated area Back of Unit Control Features Photocell Photocell Photocell Adjust Photocell Adjust Breather Gland Breather Gland NIR1Series Power adjust Pow...

Страница 3: ...max 0 08 inches 2mm wide for pot adjust Photocell following contact volt free relay contact normally open day to normally closed night Telemetry connection for remote operation Clockwise more sensitive Counterclockwise less sensitive Orange and Blue wires Photocell following contact White and Green wires Telemetry input Adjust Power to alter light intensity Remove the cover and turn the power adju...

Страница 4: ...int towards scene Optional night set up for optimum image performance Reduces performance May cause hot spots Best performance Camera 1 Adjust vertical and horizontal position of lamp to ensure full field of view illuminated 2 Tighten all fixings 3 TARGET Note Bracket can be positioned at either end of the illuminator NIR 2 and 3 only ...

Страница 5: ...5 Technical Drawings Not to scale Standard Bracketry Optional Bracketry Wall Mount Pole Mount NIR1 NIR2 NIR3 2 2 1 2 2 3 2 5 1 6 1 41 0 2 0 3 0 3 2 56 4 3 5 5 ...

Страница 6: ...7A 12V or 3 3A 24V Weight 1 6 lbs 0 73 kg 3 5 lbs 1 59 kg 7 1 lbs 3 2 kg Environment IP67 IP67 IP67 Dimensions L x W x D 3 7 x 5 5 x 3 3 95 x 140 x 84mm 5 6 x 7 7 x 3 143 x 196 x 75mm 8 x 11 2 x 3 3 203 x 285 x 83mm Integrated Control Features Built in photocell for automatic on off operation Power adjust Photocell level adjust Photocell following contact Telemetry input for remote on off operatio...

Страница 7: ...s provided to allow for drops across the cable If OK Step 2 Lamp Test Check current draw of lamp corresponds to specification on page 6 To check lamp current remove ve red lead from external power source and connect multimeter set to 10A in line with the lamp One lead of multimeter in common COM other lead into 10A socket of multimeter set multimeter to read Amps For correct current settings see p...

Страница 8: ...NI 12 10 1 RDP Security Products Inc 2691 Richter Ave Suite 124 Irvine CA 92606 Tel 949 336 4522 Fax 949 336 4526 www rdpsec com ...