RCS UTR 9442 Скачать руководство пользователя страница 1

Front Reset key

 

 2 relay, 2 C/O contact, 230V AC, 5A ; 1 SSR,12V DC, 30mA DC

Relative

Humidity

250V AC, 50 / 60 Hz, Approx 4VA

IP-65(Front side) AS per IS/IEC 60529:2001

0°C To 55°C

Up to 95% RH Non Condensing

NPN/PNP Proximity selectable & Micro switch

UTR 9442

UTR 7442

UTR 4442

UTR 4442

R

R1

R

0 1 2 3

0123

 

0123

REGENT CONTROL SYSTEMS (I) PVT Ltd

REGENT CONTROL SYSTEMS (I) PVT Ltd

REGENT CONTROL SYSTEMS (I) PVT Ltd

R1

R1

Technical Specification

96 X 96 X 50

68 X 68

44 X 44

72 X 72 X 85

48 X 48 X 95

UPPER:- 4 Digit 7 seg 0.56”,red LED Display

UPPER:- 4 Digit 7 seg 0.39”,red LED Display

LOWER:- 4 Digit 7 seg 0.4”,green LED Display

LOWER:- 4 Digit 7 seg 0.28”,green LED Display

UTR 7442

UTR 4442

UTR 9442

UTR 7442

TEMPERATURE CONTROLLER                           

REGENT CONTROL SYSTEMS

Page - 1

MADE IN INDIA

Output

Power Supply

Protection Level

Operating

(As per request)

Temperature

Input

Reset

Model

Display

Panel Cutout

UTR 9442

92 X 92

OPERATING MANUAL 

UTR 9442/7442/4442

Helpline : +91 9624004123

0 1 2 3

0 1 2 3

0 1 2 3

Memory

Selectable  YED/NO

20

19

18

17

7

14

8

13

9

12

10

11

5

16

6

15

1

2

3

4

Reset

NPN
 I/P

PNP
 I/P

+12V

GND

NO

C

NC

Relay

L

N

 

230V AC

 

 

50Hz, 4VA

!

~

 

50/60 HZ
4VA

100
250V AC

N0

+12V

I/P

NPN

I/P

PNP

GND

NC

C

L

N

1

2

3

4

5

6

7

8

9

10

11

12

13

14

RESET

RELAY

!

100  
250V AC

    

~

 

50/60 HZ
4VA

1

2

3

4

5

L

N

7

6

8

9

10

11

12

C

NO

M/S

I/P1

+12V

GND

Technical Specification

CARE

R

REGENT CONTROL SYSTEMS (I) PVT LTD

MADE IN INDIA

CARE

R

REGENT CONTROL SYSTEMS (I) PVT LTD

MADE IN INDIA

TIME

SET TIME

TIME

SET TIME

TIME

SET TIME

Size(HXWXD)

Notes:

1).  For safely purpose, key function are designed in such a way that operator will not go into
        detailed parameter setting (Previously Set) function. In this situation, in LOCK parameter, 
        YES has to be selected. If previously set parameters are to be changed, then any operator 
        has to select NO.
2).   POWER ON () : Timer starts counting as soon as it gets power supply.
3).   By default Cycle ON Mode is provided. Please refer programming guide to change to Cycle OFF
       Delay ON/ Delay OFF Mode.

PNP PROXI:- 

Short Pins 5 & 6

MICRO SWITCH:- 

Short Pins 5 & 6

                        Proxi Connection 

to 3, 4 & 5

                        M/S Connection 

3 & 4

NPN PROXI:-  

Short Pins 3 & 4

                         Proxi Connection 

to 4, 5 & 6

NO

C

NC

Relay

N0

NC

C

RELAY

RESET

RESET

NC

RELAY 2

NC

NO

RELAY 1

NPN PROXI:- Short Pins 16 & 15

MICRO SWITCH:- Short Pins 14 & 13

                        Proxi Connection to 15,14 & 13

                        M/S Connection 16 & 15

PNP PROXI:-  Short Pins 14 & 13

                         Proxi Connection to 16,15 & 14

R2

R2