3. Basic Components
2. Identification of Parts
WATER
Digital Incubator
www.R-com.co.kr
PX-20R
REAR
REAR
FRONT
Ver E 3.2
1. Safety Cautions
Electrical hazards
Be careful the details below when you use.
Setting Cautions
Be careful the details below when you use.
Do not pull the cord when
taking out the power cord,
and keep wet hands away
from connecting plug.
Do not use a damaged
power cord or loose
outlet.
Risk of electric shock or fire.
Risk of electric shock or fire.
Do not insert multiple
connecting plugs in an
outlet.
Risk of fire or electrical overload.
Never pull the plug out of
the outlet during the
incubation period.
Incubation will be interrupted.
Do not twist or crush
electric cord.
Risk of electric shock or fire.
Cleaning Cautions
Be sure to disconnect the electric cord
from the outlet before cleaning.
Clean the incubator by a
soft cloth with a neutral
detergent.
Do not spray cleanser
directly on the incubator
surface.
Do not use chemicals like wax,
benzene, alcohol, thinner,
aromatic, or lubricant, etc.
Brush away dust on the
plug with a dry cloth.
For special cleaning of
inner part per year, contact
to the service center.
Do not install under the
direct sunlight.
Do not install in dusty or
dirty environment.
Risk of fire or interference with
the incubation process.
Risk of damage or fire within
the incubator.
Do not install in excessively
cold or hot conditions,
cigarette smoke, etc.
Do not install in moist or
humid environment.
Risk of interference with
the incubation process.
Risk of fire or electric shock.
Do not use any other
non-standard parts
except those provided.
Risk of damage or hatching
failure.
Please ensure that no
small objects get into
the holes on the incubator.
Risk of electric shock or fire.
Do not disassemble or
modify the incubator in
any way.
Risk if electric shock or fire.
If the incubator sounds
strange or emits smoke
contact your service
center.
Risk of electric shock or fire.
If the incubator requires
repair disconnect from the
power supply and please
contact to your service center.
Clean the incubator
thoroughly before storing.
Install away from heat
sources.
Risk of damage to the incubator
case and interference with
the incubation process.
Do not turn the incubator
upside down.
Water will pour out of the incubator,
and view window can be dropped
or damaged.
Ensure that the incubator is
installed on a stable surface
away from edges.
Risk of damage to incubator
and eggs and user from
accidental knocks or drops.
Do not cover the
ventilating opening.
Inner temperature can rise,
interrupting incubation.
Do not install where
children or other people
can touch with easy.
Risk of knocking the incubator
or accidental interference with
the controls.
USER'S MANUAL
(Standard
)
View Window
Main Body-1
Water Cap
Power Cord
User's Manual
Tray
Main Body-2
View Window
For a clear view of
the incubation process.
( duplicated View Window )
Tray for
vermiculite( incubation sand)
and reptile eggs.
Main Body-1 Main Body-2
Tray
To facilitate water top-up
for the humidity control.
Locking Button
See description of
the function and operation.
Digital Control Center
Power Connecting
(the rear)
For connecting
power cord.
For circulating warm air
For inlet of air
from outside
Water Cap
Air inlet vent
Vents for air circulation
4. How to Assemble
5. How to Replace Fuse
CAL
CAL
TEMPERATURE
HUMIDITY
TEMP.GAP
HEATING
WATER EMPTY
HUMIDIFICATION
incubator
TEMP +
TEMP +
TEMP -
TEMP -
HUMI -
HUMI -
HUMI +
HUMI +
D.T.G.
D.T.G.
SET
SET
Daily Temp. Gap Function
Temp. UP Button
Daily Temp. Gap Lamp
Lamp ON when Operation
▶
What is Daily Temperature Gap Function?
It is artificial promotion of nature condition of the highest temperature time zone.
By upraising the temperature at the specific time zone, it helps achieving the highest hatching success.
Temp. Display
Temp. DOWN Button
(Lighting when working)
Heater Lamp
Humidity UP Button
Humidity DOWN Button
Setting Button
Humidity Display
(Lighting when working)
Humidification working lamp
(Blink with water shortage)
Water Supplement Lamp
7. Operation Part
8. Easy Function Operation
Daily Temp. Gap ON /
Daily Temp. Gap OFF
(Three hours operation per day)
/ +1.5
℃
D.T.G.
D.T.G.
Daily Temperature Gap
Setting
Lock the three locking
buttons at the front and rear
of the incubator.
Insert the power cord
in the socket at the back
of the main body.
REAR
REAR
FRONT
View Window
Main Body-2
Tray
Main Body-1
ⓐ
ⓑ
900cc
6. Before use
Environment conditions of the incubation room
for the installation of reptile incubator.
( Temp.: 22~25
℃ /
Humidity: 30~50% )
4. Bury a low half of the eggs into the Vermiculite as[Fig.-1] and fix them.
(Check the conditions of the eggs once a week. Remove unfertilized eggs,
incompletely developed eggs, eggs covered with mold.)
5. Check the water for humidification everyday and fill it up as
shown in Fig - 4.
Stop supply of the water when styrofoam ball floats.
Do not reuse Vermiculite( incubation sand) after hatch.
Remove water from the tank before moving the incubator.
Otherwise the incubator can be out of order.
2. Humidification heater part [ Fig.-5] of the main body-1 should be soaked
inside of water tank when assembling with main body-2.
Be sure to check this, and cover the view window for connecting power cord.
REAR
REAR
FRONT
ⓐ
ⓒ
ⓑ
ⓓ
[ Figure - 2 ]
Do not apply force or shock to heater on the upper part of the body.
It may be the cause of failure.
Some foreign body can be stick to the heater part after hatching,
but there is no problem. (Refer to the "How to Clean)
[ Figure - 4 ]
[ Figure - 1 ]
[ Figure - 6 ]
Water
Water
Vermiculite( incubation sand)
Vermiculite( incubation sand)
Vermiculite( incubation sand)
75cc
75cc
75cc
75cc
If the incubation room temperature does not meet
the required temperature, it can not be controlled
automatically with the set incubation conditions.
Room temperature should be about 4
℃
lower
than incubator setting temperature.
REAR
REAR
FRONT
[ Figure - 3 ]
③
ⓔ
1000cc
1. Before starting incubation, fill water into the water tank
ⓒ
,
ⓓ
of main body-2
as [ Fig.-2 ] for humidification.
If the incubation room is not properly controlled for high humidity (90~95%),
pour 75cc of water into four edges of the tray. ( See Fig. - 6)
And, pour 1000cc of water at the main body-2. [ Fig.- 3 ]
▶ In case of low humidity incubation (70% ~ 85%): Fill the vermiculite( incubation sand)
which is to be purchased separately into the small incubating tray as shown in
[Fig.- 1]
ⓑ.
▶ In case of high humidity incubation (90% or more): In case the incubating environment is to be maintained 90%
or higher in humidity, fill the small incubating tray with 900cc of water as shown in
[Fig.- 1 ]
ⓐ and
put the vermiculite into it as shown in
[Fig.- 1 ]
ⓑ before mixing them.
That would facilitate the control of high humidity and remove the need of water filling.
▶ If you are going to incubate without water in the incubator,
you should turn off humidification function.
(Refer to How to turn off Humidification Function)
3. After setting the incubation environment of the egg, install tray
inside of the incubator and operate it for 30 to 40 minutes
and put eggs into the tray.
"OFF"
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
HUMI -
HUMI -
HUMI -
HUMI -
HUMI +
HUMI +
TEMP -
TEMP -
TEMP -
TEMP -
TEMP +
TEMP +
TEMP +
TEMP +
℃↔℉
How to Operate
Function
Explanation
Cels. / Fahr.
interchangable
How to change Cels. or Fahr.
Temp. Setting
Humidity Setting
How to turn off
Humidification Function
Setting of required temp.
Setting of required humidity.
Initialization
※
If you want to change setting value, keep pressing "SET" button and change the value.
Incubator Initialization
(Factory Setting)
REFER TO "HOW TO START INCUBATION" FOR MORE INFORMATION.
UNDER 40%
In case of low humidity
incubation
REAR
REAR
FRONT
[ Figure - 5]
Humidification
Heater Part
▶
Replace with new fuse.
( 250V 2.0A
Ø
5*20mm )
▶
When the machine failed to
power on even if you pluged in,
remove the fixing piece like
the picture by screwdriver.
▶
You can find assembled PCB
when open the cover.
Remove faulty fuse with screwdriver.
Power Failure Alarm Function
Blick with power failure
(to remove, press SET button)
(Setting Value check)
AU
TO
ELE
X
AU
TO
ELE
X
AUTO
EL
EX
AUTO
EL
EX