background image

LockR 

Battery replacement

 

LockR battery replacement.pdf 

© RCO Security AB. All rights reserved. May 2021.

 

LockR battery replacement 

The low battery warning (a yellow lamp and possibly a beep, depending on 
programming) begins when approximately 10% of the battery capacity 
remains. Recommendation: Replace the batteries promptly when the 
battery warning begins.  

When scheduling battery replacement in a large facility with outdoor units, it is best to 
schedule it in the autumn or early winter. This is because battery usage is greater at lower 
temperatures.  

When you replace the batteries, the unit’s clock and function settings are saved for 
approximately 3 hours.  

Battery specifications 

The unit requires two primary batteries of type CR2 (IEC CR15H270) that fulfil battery 
safety standard IEC 60086-4.  

Warning! 

Only the above type of battery may be used. Danger may arise when using 

other types of batteries. Replace both batteries at the same time, using two batteries 
from the same manufacturer.  

Warning! 

Incorrect use of lithium batteries can cause fire or damage. Read the 

warning texts on the battery packaging.  

Sensitive parts in LockR Cylinder! 

LockR Cylinder contains ESD-sensitive components. When replacing the batteries, 
avoid touching the product's electronics. It is also important not to scratch or damage 

the surfaces shown by the arrows. Doing so can damage the product’s seal against 
moisture and water (IP67). 

 

 

 

 

 

 

This does not apply to LockR Cabinet or LockR Rotary Switch. Nor does it apply to LockR 
Cylinder MIF80A

x, which is intended for indoor use only and has no IP rating. 

!

 

!

 