RCF MZ 8060 Скачать руководство пользователя страница 1

USER MANUAL

MZ 8060

 

-

 AUDIO MATRIX WITH 8 AUDIO 

INPUTS AND 6 AUDIO OUTPUTS

Содержание MZ 8060

Страница 1: ...USER MANUAL MZ 8060 AUDIO MATRIX WITH 8 AUDIO INPUTS AND 6 AUDIO OUTPUTS...

Страница 2: ......

Страница 3: ...rity function ducking AUDIO OUTPUTS AND SLAVE UNIT CONTROLS audio output settings equalizer limiter MIXER MATRIX matrix nodes GROUPS control group mute group assignment of audio inputs and outputs to...

Страница 4: ...event the risk of electric shock never open this product there are no parts inside that the user needs to access The mains plug is used as the disconnect device and it shall remain readily operable 3...

Страница 5: ...m in addition to those which are strictly acoustic such as sound pressure angles of coverage frequency response etc 11 Hearing loss Exposure to high sound levels can cause permanent hearing loss The a...

Страница 6: ...outputs have removable screw terminals and are fully configurable Two MZ 8060 MASTER and SLAVE can be linked each other to get a 16 input 12 output matrix through RJ 45 digital ports on their rear pan...

Страница 7: ...s by linking together two MZ 8060 Configurable ALC Automatic Level Control when a noise detection microphone is connected to the input no 8 Either USB link standard or RDNET link through the optional...

Страница 8: ...o input 2 OUTPUTS LEDs each LED indicates the signal level of its respective audio output NOTE each LED 1 and 2 is off when its audio signal level is below 60 dBFS green 60 dBFS orange 12 dBFS red in...

Страница 9: ...s the SLAVE unit When blinking the MASTER unit is not linked to the SLAVE or vice versa or due to a LINK fault 8 HOST USB type B port to link a computer PC locally REAR PANEL 9 PAGING CONSOLE input 1...

Страница 10: ...oftware Note logic outputs cannot be used to power other devices i e relays Output voltage can be either 5 V high or 0 low 18 24 VDC output two positive 24 V dc pins and two ground pins 24 V dc output...

Страница 11: ...se this product The foregoing provision is effective even if RCF S p A has been advised of the possibility of such damages Even if the SOFTWARE has any material verifiable and reproducible program err...

Страница 12: ...with either Microsoft Windows Vista or 7 or later operating system having an available USB port The operating system shall also have the drivers for the emulation of the serial RS 232 interface via th...

Страница 13: ...h a suitable cable the computer USB port to the one of the MZ 8060 audio matrix labelled HOST 8 Run the RDNET software in Windows click Start Programs RCF RDNet RDNet or double click RDNet icon on the...

Страница 14: ...select Show Obj Details to open the audio matrix setting window To upgrade the MZ 8060 firmware main menu Advanced Firmware Upgrade refer to the RDNET user manual The main window includes the 8 MASTER...

Страница 15: ...eset all MZ 8060 PRESET MANAGER It is possible to store and recall up to 16 different presets Click UNIT SETTINGS in the main window to open the Global settings window which includes the preset manage...

Страница 16: ...ting from 0 lowest to 10 highest for the ducking function automatic level attenuation of one or more audio inputs when a signal is detected at the input with the highest priority level INPUT n 8 audio...

Страница 17: ...he filter is disabled by pass PEQ parametric equalizer that allows to adjust the level at the settable centre frequency and specify the Q factor the adjusted level can be widened or narrowed SHELVING...

Страница 18: ...ces commands STORE it sends and stores the equalization to MZ 8060 SEND it sends without storing the equalization to MZ 8060 For each filter frequency and gain can be adjusted either graphically throu...

Страница 19: ...h the mouse the red points in the graph THRESHOLD adjusts the level above which the compressor compresses the signal OUT GAIN adjusts the output gain useful to minimize the signal attenuation due to c...

Страница 20: ...ding to the compression expansion ratio To access AGC parameters of a single input click EDIT on the respective channel and select the DSP window THRESHOLD adjusts the level above which the AGC operat...

Страница 21: ...lect the DSP window THRESHOLD adjusts the level below which the noise gate attenuates a signal GATE RANGE adjusts the signal reduction when its level is below the threshold Attack adjusts the noise ga...

Страница 22: ...ion in order to avoid signal distortion too high or an insufficient level BM 3003 SETUP To access the common BM 3003 paging microphone settings click EDIT of the INPUT 1 and select the DSP window Each...

Страница 23: ...p below the signal level bar Note set the input 8 to MIC INPUTS SETUP When the ambient noise detected by the microphone linked to the input 8 is above the threshold only audio outputs of the same unit...

Страница 24: ...ction of the doubling of the number of mixed inputs For example if the value is set to 3 dB with two open inputs the mixed signal will be reduced by 3 dB with four open inputs by 6 dB with eight open...

Страница 25: ...input channel by PRIORITY parameters Click DUCKING in the main window The THRESHOLD fader only refers to audio input s having the highest priority level and allows to set the threshold signal level ex...

Страница 26: ...R SLAVE as LINK CONFIG choice On the far right of the software main window there are two buttons to choose which MZ 8060 needs to be edited click either MASTER to access all MASTER unit parameters or...

Страница 27: ...put no 8 Read the Automatic Level Control ALC manual section DELAY 6 delay time setting in milliseconds up to max 5 seconds applied to the output signal Except in specific cases e g second line loudsp...

Страница 28: ...ilter is disabled by pass PEQ parametric equalizer that allows to adjust the level at the settable centre frequency and specify the Q factor the adjusted level can be widened or narrowed SHELVING HIGH...

Страница 29: ...Z 8060 SEND it sends without storing the equalization to MZ 8060 For each filter frequency and gain can be adjusted either graphically through the mouse by dragging the little coloured square or in an...

Страница 30: ...TER Click MATRIX in the software main window to access the audio matrix window to match the 8 MASTER inputs plus the 8 SLAVE inputs if available and either the 6 MASTER outputs A F buses or the 6 SLAV...

Страница 31: ...31 ENGLISH...

Страница 32: ...trol of the automixer no 1 which automatically adjusts the audio input level according to the number of open channels A MIX2 assigns the node to the control of the automixer no 2 alternative to the au...

Страница 33: ...to a group simultaneously acts on all audio inputs and outputs assigned to that group For each MZ 8060 MASTER or SLAVE it is possible to set up to 16 CONTROL groups and 16 MUTE groups Before editing...

Страница 34: ...t output selection The green light beside when lit means that at least one input output has been selected if the light is off the group has not been configured yet ENABLE toggles the group keep it on...

Страница 35: ...T logic input GPIN Click FORCE ON OFF in the main window M INPUT n MASTER unit input S INPUT n SLAVE unit input AUDIO INPUT SETTINGS FORCE ON sets how much up to 20 dB the audio signal level will be i...

Страница 36: ...the logic input read the next paragraph ChannelID parameter depending on the selected FUNCTION it can be either a preset or an audio input output or a group Momentary the selected function is applied...

Страница 37: ...ut level use the slider to adjust MASTER CTRL GRP INCR CTRL GROUP It increases the selected MASTER unit CTRL GROUP signal level use the slider to adjust MASTER CTRL GRP DECR CTRL GROUP It reduces the...

Страница 38: ...ection of the function assigned to the logic output read the next paragraph ChannelID parameter depending on the selected FUNCTION it can be either a preset an audio input output or a MUTE group GPOUT...

Страница 39: ...input is muted to the MASTER unit audio outputs MUTE MASTER OUTPUT OUTPUT The logic output will get activated when the selected MASTER unit audio output is muted MASTER MUTE GROUP MUTE GROUP The logi...

Страница 40: ...T IN OUT PLUG board 4 Insert the AC RDNET IN OUT PLUG board into the MZ 8060 automixer slot and fasten it with the 4 screws Each of the eight RDNET CONTROL 8 ports can be connected to max 32 daisy cha...

Страница 41: ...gned to the device fault indication Set the JMP1 internal jumper on the digital board to the position 1 2 in order to enable the user software control JUMPER POSITION FUNCTION JMP1 1 2 The RL1 logic o...

Страница 42: ...dance Frequency response Dynamic range Distortion THD N 1kHz 22 dBu ELECTRICAL DATA Power Phantom power MECHANICAL DATA Dimensions l h p Net weight 24 bits 48 kHz 24 dBu balanced 50 dB 24 dBu 50 20 Hz...

Страница 43: ...r if its execution fails for any reason e g the specified controller type does not exist or a given parameter value is out of range the device will respond with a string as the following NACK COMMAND...

Страница 44: ..._LABEL Retrieves the label of either an audio input output channel or a preset or a mute control group or even a GPI logic input GPO logic output Generic command syntax is the following GET_LABEL CONT...

Страница 45: ...d to the above command with a string similar to the following ACK GET_LABEL M_MGRP 15 FOO BAR CR where FOO BAR is the current label of 15th master mute group EXAMPLE 2 GET_LABEL PRST 3 CR Returns thir...

Страница 46: ...roups Input channels 1 to 8 belong to the master unit input channels 9 to 16 belong to the slave unit For M_MTX and S_MTX controller types PARAMETER 1 is the matrix input channel and must be in the ra...

Страница 47: ...to 16 belong to the slave unit PARAMETER 2 is the target mute state of the addressed input channel output channel or mute group for all controllers types except for M_MTX S_MTX and ALL_OUT It must be...

Страница 48: ...lave control group fader levels Input channels 1 to 8 belong to the master unit input channels 9 to 16 belong to the slave unit For M_MTX and S_MTX controller types PARAMETER 1 is the matrix input cha...

Страница 49: ...RP to update a master device control group fader level S_CGRP to update a slave device control group fader level M_MTX to update a master device audio matrix node level S_MTX to update a slave device...

Страница 50: ...d to calculate second parameters of other level controllers types If command execution succeeds the device will respond to the above command as follows ACK SET_LEVEL CONTROLLER TYPE PARAMETER 1 PARAME...

Страница 51: ......

Страница 52: ...RCF S p A Italy Via Raffaello Sanzio 13 42124 Reggio Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it Except possible errors and omissions RCF S p A reserves the right to make...

Отзывы: