Summit Alarm Panel Interface
General description
The PC100 when made for the Summit application will interface the Electronics Line Summit alarm panel to the
IRC2000 access control system.
1)
(RS232, RS485, TCP/IP) Host – for communication with the PC software running Integra32™.
2)
(RS485) Panel – for connection to the LSCP bus on the Summit alarm panel.
3)
(RS485) IRC – for connection to the Access control system.
All channels are programmed for a baud rate of 9600 8-bits no parity and all Integra32™ panels need to be
programmed for 9600 baud.
All activity is synchronized to the Summit LSCP bus. If the bus is disconnected all activity on the PC100 will halt.
The PC100 acts like a zone expander to the Summit panel allowing up to 32 zones. Each zone is mapped to an
element in the IRC network. The state of each element in the IRC network will cause a zone to appear open or
closed.
The PC100 acts like an IRC panel at address 32 to the host. The host can poll the PC100 to see if it is online,
request status, write to memory, and update flash memory.
IRC2000 panels connected along with the PC100 must be running firmware version 76 or higher for the
PC100 and the IRC2000 panels to function together correctly.
Programming an Arm/Disarm key-switch
When an Access Granted message is used as a source for an input, the status of the alarm panel is checked before
execution is allowed. If the function is to disarm the panel and the panel is already disarmed no action will take
place. Conversely if the function is to arm the panel and the panel is already armed the command will be ignored.
The key-switch functionality works on the basis of a momentary contact. Whenever the button is pushed the alarm
panel will change states if possible when the switch returns to its closed position. It is not allowed to arm if an
exterior zone is open for example.
Each zone can be programmed manually through the keyboard interface.
There are two types of arming allowed - STAY and AWAY.
Содержание Integra32
Страница 7: ...Chapter 1 Intelligent Field Panel RBH Access Technologies Inc Integra32 Hardware Guide 3 ...
Страница 18: ...Chapter 2 Intelligent Field Panel Integra32 Hardware Guide RBH Access Technologies Inc 14 ...
Страница 23: ...Chapter 2 Intelligent Field Panel RBH Access Technologies Inc Integra32 Hardware Guide 19 Connection Details ...
Страница 39: ...Specifications RBH Access Technologies Inc Integra32 Hardware Guide 35 S p e c i f i c a t i o n s ...
Страница 51: ...Appendix 1 Specification Sheets RBH Access Technologies Inc Integra32 Hardware Guide 47 ...
Страница 54: ...Appendix 1 Specification Sheets RBH Access Technologies Inc Integra32 Hardware Guide 50 ...