background image

 

 

 

 

 

 

5 Megapixel, 360 View IR Mini-Dome

 

LP500-360 

 

 

 

 

 

 

 

 

User Manual 

 

9.20.2012 

Содержание LP500-360

Страница 1: ...5 Megapixel 360 View IR Mini Dome LP500 360 User Manual 9 20 2012 ...

Страница 2: ... Definition Optional 5 2 Camera Cabling 6 2 1 Connect Power 6 2 2 Connect Ethernet Cable 6 3 System Requirements 7 4 Camera Access 8 5 Setup Video Resolution 13 6 Configuration Files Export Import 14 Appendix A Technical Specifications 15 Appendix B Delete the Existing DC Viewer 17 Appendix C Setup Internet Security 18 ...

Страница 3: ... view The LP500 360 is compatible with the user friendly razberi ServerSwitch NVR for quick plug and play installation 1 1 Features i Progressive Scan CMOS Sensor ii 5M resolution iii Dual Streams Full HD 1080P real time D1 real time iv Quad Streams support v Quad Streams Compression H 264 Baseline Main High Profile MJPEG vi 360 Panorama View vii ePTZ viii Quad View ix Tampering Alarm x Wide Dynam...

Страница 4: ...Security Screw 1 Security Torx Power Terminal Block x1 Quick Guide CD All In One Cable Optional NOTE The supplied self tapping screws are mainly for softer substrate material installation such as wood For other installation environments such as cement wall it is required to pre drill and use plastic anchors before fastening the supplied self tapping screw on the wall ...

Страница 5: ...tor Pin Definition Remarks 1 Power DC 12V 1 Power Power connection 2 Reserved 3 GND AC 24V 1 Power 1 2 Earth GND 3 Power 2 2 RJ 45 10 100 Mbps Ethernet PoE 3 Alarm Audio I O Alarm Audio I O 4 Reset Button Restore to default setting Press the button with a proper tool 5 Micro SD Card Slot For video recording storage All in One Cable is required for Power Alarm and Audio I O utilization ...

Страница 6: ...ion 2 ALM_IN 3 ALM_OUT 4 ALM_OUT 3 Power DC Jack DC 12V Power connection Power Wires Red AC 24V Remove DC Jack connector head and apply AC 24V with Red and Black wires as shown in the diagrams below Black AC 24V 4 Alarm Audio I O 1 GND Two way audio transmission Alarm connection 2 Line In 3 Line Out 4 5 ALM_IN 6 ALM_IN 7 ALM_OUT 8 ALM_OUT 5 Power Wires Red DC 12V AC 24V Power connection Black DC 1...

Страница 7: ...egory 5 Ethernet cable is recommended for the network connection Cable length shall not exceed 100 meters Connect one end of the Ethernet cable to the RJ 45 connector of the LP500 360 and the other end of the cable to the network switch PC or Razberi ServerSwitch NOTE In some cases you may need use an Ethernet crossover cable when connecting the LP500 360 directly to the PC Check the status of the...

Страница 8: ...below Items System Requirement Personal Computer Minimum 1 Intel Core i5 2430M 2 4 GHz 2 4 GB RAM Recommended 1 Intel Core i7 870 2 93 GHz 2 8 GB RAM Operating System Windows VISTA Windows XP Windows 7 Web Browser Microsoft Internet Explorer 6 0 or later Firefox Chrome Safari Network Card 10Base T 10 Mbps or 100Base TX 100 Mbps operation Viewer ActiveX control plug in for Microsoft IE ...

Страница 9: ...utton on the top side Step 2 The security alert window will pop up Click on Unblock to continue Device Search Step 3 Click on Device Search again and all the discovered IP devices will be listed in the page The LP500 360 s default IP address is 192 168 0 250 Step 4 Double click or right click and select Browse to access the camera directly via web browser Step 5 Enter the default username and pass...

Страница 10: ...razberi technologies 9 NOTE It is strongly advised that administrator s password be altered for the security concerns Refer to Full HD Multiple Streams IP Camera Menu Tree for further details ...

Страница 11: ...the LP500 360 Step 4 Click on the Device Search button to search all the devices Then select the LP500 360 with the correct MAC address Double click on the LP500 360 and the login window will appear Step 5 Enter User name and Password to access the LP500 360 Installing DC Viewer Software Online For the initial access to the LP500 360 a client program DC Viewer will be automatically installed to yo...

Страница 12: ...allation Step 2 The status bar will show the installation progress After the installation is completed click on Finish to exit the installation process Step 3 Click on Finish to close the DC Viewer installation page Once the DC Viewer is successfully installed the LP500 360 s Home page will be able to correctly display as shown below Ceiling Mount Installed Camera ...

Страница 13: ...razberi technologies 12 Wall Mount Installed Camera Note Please refer to Full HD Multiple Streams LP500 360 Menu Tree for more button function detail ...

Страница 14: ...ndly browser based configuration interface Video Format can be found under this path Streaming Video Format The default value of Video Resolution is H 264 2592 x 1994 10 fps H 264 720 x 480 10 fps For more Video Resolution combination detail please refer to Appendix Video Resolution Click on Save to confirm the setting ...

Страница 15: ...and retrieve data by uploading an existing configuration file to the LP500 360 Export Users can save the system settings by exporting the configuration file bin to a specified location for future use Click on the Export button and the popup File Download window will come out Click on Save and specify a desired location for saving the configuration file Upload To copy an existing configuration file...

Страница 16: ...rt IR Light Sensor Tampering Alarm On Off Audio Type Built in Speaker Max 2W Mono Microphone or Two way Audio Line in Line out Compression G 711 G 726 Network Interface RJ 45 10 100 Mbps Ethernet Video Compression H 264 Baseline Main Profile High Profile MJPEG Video Streaming Single Stream 2592 x 1944 10 fps Single Stream 2048 x 1536 15 fps Simultaneous H 264 1080p 25 30 fps MJPEG D1 25 30 fps Sim...

Страница 17: ...Block Ethernet RJ 45 All in one Cable Audio I O Line in Line Out Alarm 4 Pin Wire Cables Power DC 12V DC Jack AC 24V Power Wire Cables AC 24V AC 24V General Operating Temperature 10 C 50 C 14 F 122 F Humidity 10 90 No Condensation Weatherproof Standard Rugged Camera IP66 Dimension Ø 149 x 45 8 mm Ø 5 87 x 1 80 in Weight 350 g 0 77 lbs Power Source DC 12V AC 24V PoE Power Consumption Max 12W Regula...

Страница 18: ...grams list select DCViewer and click on the button Remove to uninstall the existing DC Viewer Deleting Temporary Internet Files To improve browser performance it is suggested to clean up the all the files in the Temporary Internet Files The procedure is as follows Step 1 Click on the Tools tab on the menu bar and select Internet Options Step 2 Click on the Delete button under Browsing history sect...

Страница 19: ...ontrols and plug ins settings The Security Settings window will pop up Step 3 Under ActiveX controls and plug ins set ALL items as listed below to Enable or Prompt Please note that the items vary by IE version ActiveX controls and plug ins settings 1 Allow previously unused ActiveX controls to run without prompt 2 Allow Scriptlets 3 Automatic prompting for ActiveX controls 4 Binary and script beha...

Страница 20: ...razberi technologies 19 ...

Отзывы: