SNV-12 Operations Manual
4-10
4.8.2
Voting Controls
Use the SELECT or DISABLE toggle switch selection on the individual Site Voter Modules if
it is necessary to remove a site from consideration from voting (DISABLE) or cause a site to be
voted without regard to its signal quality (SELECT). The SELECT mode will not take affect
unless the site has active COR (is unsquelched). No other front panel operational control is
required.
The SVM front panel LEDs will provide a constant indication of each site's status. The
VOTED LED lights to indicate the site that's currently voted. The UNSQUELCH LED must
be lit for any site to be eligible for voting. This LED lights to show active COR, which means
that the associated receiver is unsquelched and is sending a valid signal. The evidence for this
depends on the COR type used, it could be the presence of a hardwired COR input, the
detection of audio in the RX signal, or the absence of a pilot tone. The TX LED will light to
show that the Voter has been commanded to send transmit audio and keying commands to the
associated transmitter. The FAULT LED flashes during the power-up sequence and lights to
indicate the detection of a fault during power-up bit testing, or when a line fault is detected
(COR signal with no audio presence, or absence of pilot tone with no audio presence, for a
prolonged period). Faulted sites are removed from consideration for voting until the fault is
cleared. The Peak and Normal LEDs are visible at the RX Input Monitor/Adjust access
window in the SVM-2‟s front panel.
The voted audio or a voted audio/console TX audio combination may be monitored via the
Console Interface Module, using its speaker or an external speaker. The volume knob on the
CIM front panel controls the audio level to the speaker and the external speaker; the speaker
switch may be used to turn off signal to either the internal or external speaker.
The Fault LED on the CPM will light if this module fails its own start-up test or if it cannot
communicate with one of the Site Voter Modules. The CPM knows if an SVM is installed but
not communicating; if it‟s not obvious which SVM has failed, simply remove SVMs one at a
time until the CPM Fault LED clears. The CIM PEAK and NORM LEDs show the presence
and level of the console TX Input Audio signal. The NORM LED is lit when audio is present
at normal levels. If the levels are correctly set, the PEAK LED will flash during peaks in
speech. If the console audio is too low, the PEAK LED will never light; if levels are too high,
it will be lit for more than just brief flashes on voice peaks. The FAULT LED on the CIM is
illuminated if it fails its start-up test.
4.9
Remote Control
The SNV-12 may be controlled and monitored remotely via its serial command interface (RS-
232 or Telnet) or the web based user interface (see Sections 3.11.3 and 6). As many as three
SNV-12s may be connected together to create a voting system of up to 36 sites. This type of
expanded system has a Master and two Expansion units; the master unit controls both
Expansion units, and only the master can be remotely controlled. The Master then controls
each Expansion chassis.
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......