background image

Chapter 1: Control Head Installation

7

1.3 Power supply (Stand-alone operation)

Caution: The ST30 Speed must only be connected to a 12V supply.

+

+

+

+

+

SEATALK

SP

EE

D

D585

12V Supply

Red

Screen

5A

For stand-alone operation, use the 1 metre cable supplied with the
instrument.

1.

Connect the moulded power supply plug to either SeaTalk connection
on the rear of the instrument and run the free end back to the
vesselÕs distribution panel.

2.

Cut the power cable to length and connect the red wire to the positive
12V terminal and the screen to 0V. Protect with a 5A circuit breaker
or fuse.

1.4 Power supply (SeaTalk operation)

If the ST30 Speed is to be connected to an existing SeaTalk system use a
Standard SeaTalk Extension or Interface cable.

Autohelm

Autohelm

Autohelm

Power

Extension Cable

D628

Содержание AUTOHELM ST 30 SPEED

Страница 1: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO SPEED Operation and Installation ST 30...

Страница 2: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO Nautech Limited Anchorage Park Portsmouth P03 5TD England Telephone 0705 693611 Fax 0705 694642...

Страница 3: ...DISPLAY TM SPEED TRIP TOTAL MAXIM UM AVERAGE D582 Autohelm and SeaTalk are registered Trade Marks of Nautech Limited Autohelms policy of continuous improvement and updating may change product specifi...

Страница 4: ...rough hull with 10m cable and 1 8in spade connectors 0 to 32 knots 7 Instrument cover 8 Operation and installation handbook 9 High speed paddlewheel 2 to 45 knots 10 Daisy chain cable DISPLAY SPEED TR...

Страница 5: ...Cabling 13 Chapter 3 Fault Finding 14 Chapter 4 Maintenance 15 4 1 Instrument 15 4 2 Transducer 15 4 3 Cabling 15 4 4 Advice 15 Chapter 5 Operation 16 5 1 Display Key 16 Trip Distance display 17 Tota...

Страница 6: ...ion the ST30 Speed can be used as a stand alone master instrument or can be set to repeat speed information from the SeaTalk bus The ST30 Speed will display the following information Boat speed Log Tr...

Страница 7: ...iewed at eye level protected from physical damage at least 230mm 9in from a compass at least 500mm 20in from radio receiving equipment accessible from behind for ease of installation and cable running...

Страница 8: ...Note To allow protective covers to be fitted adjacent instruments should be sited not less than 6mm 0 24in from each other 116mm centre to centre min 3 Drill two 5mm 0 2in diameter holes for the fixi...

Страница 9: ...r supply plug to either SeaTalk connection on the rear of the instrument and run the free end back to the vessel s distribution panel 2 Cut the power cable to length and connect the red wire to the po...

Страница 10: ...eed is supplied with a daisy chain cable that allows adjacent ST30 instruments to be linked together The daisy chain cable supplies power to adjacent instruments and allows data to be transmitted and...

Страница 11: ...nsducer Installation 9 Chapter 2 Transducer Installation 2 1 Connection to instrument The transducer is supplied with 10m 32 5ft of cable that plugs directly into the back of the instrument SEATALK S...

Страница 12: ...ion 2 3 which contains instructions on how to fit the high speed paddlewheel supplied 2 3 Paddlewheel replacement If the high speed paddlewheel supplied is to be fitted or the existing paddlewheel to...

Страница 13: ...the speed transducer 3 and retain with the pin 6 Note The paddlewheel is correctly orientated when the working surfaces of each paddle are facing forwards 6 Assemble the speed transducer 3 to the thr...

Страница 14: ...ough hull For accurate speed readings locate the speed transducer in the shaded clear flow areas as shown D587 The transducer should also be ahead of propellers 10 W L length minimum at least 150mm 6i...

Страница 15: ...Z119 transduc ers are to be used the following modification must be carried out on the transducer lead 1 Using a pair of wire cutters remove the moulded plug from the end of cable 2 Strip the outer ca...

Страница 16: ...supply Check cabling and security of connectors Check circuit breaker Return ST30 Speed for repair No speed information Transducer cabling problem or fouled Clean paddlewheel No exchange of informatio...

Страница 17: ...e used to clean the ST30 Speed instrument if the instrument is dirty clean with a soft damp cloth 4 2 Transducer Refer to the Installation and Maintenance instructions supplied with the transducer 4 3...

Страница 18: ...hen the ST30 Speed is powered on the instrument displays Boat Speed Knots DISPLAY SPEED TRIP TOTAL MAXIMUM AVERAGE D605 5 1 Display Key Each press of Display cycles the following menu Trip distance To...

Страница 19: ...ay will flash on and off before resetting to zero Nm DISPLAY TM SPEED D601 TRIP TOTAL MAXIMUM AVERAGE Total Distance display Press Display to select Total Distance The Total Distance display shows the...

Страница 20: ...n knots or mph Knots DISPLAY TM SPEED TRIP TOTAL MAXIMUM AVERAGE D603 2 The maximum speed display is reset by pressing for one second Knots DISPLAY TM SPEED TRIP TOTAL MAXIMUM AVERAGE D604 Average Spe...

Страница 21: ...TM SPEED TRIP TOTAL MAXIMUM AVERAGE D606 5 2 Light Key The key controls the level of instrument illumination There are 3 levels with level 3 the brightest DISPLAY TM SPEED TRIP TOTAL MAXIMUM AVERAGE...

Страница 22: ...distance in nm or miles To select the calibration menu press and hold Displayand After 2 seconds the display will show CAL Cal DISPLAY TM SPEED TRIP TOTAL MAXIMUM AVERAGE D590 Each press of Display w...

Страница 23: ...IP TOTAL MAXIMUM AVERAGE D592 Log units selection nm miles 1 When Units Selection nm miles is cycled the display shows nm or miles Cal DISPLAY SPEED TRIP TOTAL MAXIMUM AVERAGE D593 NM TM 2 Press to ch...

Страница 24: ...calibrated to suit the characteristics of the vessel This is a simple operation and is carried out as follows 1 Choose two charted points that are approximately 1nm apart Approximately 1Nm Point 1 Poi...

Страница 25: ...Distance Enter calibration factor CF 1 Press Display and for 2 seconds until CAL is displayed Cal DISPLAY TM SPEED TRIP TOTAL MAXIMUM AVERAGE D590 2 Press Display until Log Calis shown in the window...

Страница 26: ...tion Lock Unlock The lock unlock feature removes the risk of accidentally changing tie calibration values set for log calibration shallow alarm etc For securii the calibration lock unlock feature is a...

Страница 27: ...ress A and V together CO Calibrtion locked i e IX access Cl Calibration unlocked i e normal access 3 Mode selection is altered using A key Return to normal display Press and hold Display and After 2 s...

Страница 28: ...s speed information onto the SeaTalk bus The ST30 Speed can be set up as a Repeater repeating speed information already on the SeaTalk bus Repeater mode is set as follows 1 Press and hold Display and...

Страница 29: ...TOTAL MAXIMUM AVERAGE D610 Note Normal calibration is not available when the ST30 Speed is set to Repeater mode Return to normal display To exit calibration and return to speed press and hold Displaya...

Страница 30: ...9 knots or mph 0 1 increments Maximum speed 0 to 99 9 knots or mph 0 1 increments Log 0 to 5999nm or miles 0 1 increments to 99 9 and 1 0 to 999 Trip distance 0 to 999nm or miles 0 01 increments to 9...

Страница 31: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO Nautech Limited Anchorage Park Portsmouth P03 5TD England Telephone 0705 693611 Fax 0705 694642...

Страница 32: ...TOP EDGE BLEED MASK FOR 2 COLOUR SEATALK LOGO Nautech Limited Anchorage Park Portsmouth P03 5TD England Telephone 0705 693611 Fax 0705 694642...

Отзывы: