3 Configuration & Maintenance
10000000584
18
Edition:002
► Tab. 3: Ship Network Settings
Element
Description
Use DHCP
The device uses DHCP to dynamically obtain an IP
address in the ship network. This is the default behav-
ior.
IP address
If DHCP is not in use, this is the IP address of the de-
vice in the ship network. Please select a unique IP,
which is different from the IP address in the
net-
work.
Subnet mask
If DHCP is not in use, this is the subnet mask of the
ship network. The default value is
255.255.255.0
.
Gateway
If DHCP is not in use, this is the IP address of the
gateway which connects the ship network to the Inter-
net.
Activate Use of Internet
If deactivated (not advised), the eLog device will not
attempt to connect to the logbook cloud services for
cloud-based storage of logbook data or download of
software updates.
4.
Select the softkey
Safe
.
► The device reboots.
5. Close the browser window.
► After approximately 3 minutes the electronic logbook can be used again. The
changed settings are now active.
3.1.2
Configure LWE Network
Requirements
• You must be logged in as an administrator.
About this task
The eLog is able to send logbook data to the VDR and alerts to the CAM-HMI via IEC
61162-450 Ed. 2 communication on
ethernet port 0
.
Procedure
1. Select the softkey
LWE Network
in the Gateway Configuration menu, see
.
► The menu
LWE Network
opens.
Содержание eLog
Страница 4: ...Table of Contents 10000000584 II Edition 002 ...
Страница 6: ...List of Figures 10000000584 IV Edition 002 ...
Страница 8: ...List of Tables 10000000584 VI Edition 002 ...
Страница 10: ...List of Abbreviations 10000000584 VIII Edition 002 ...
Страница 46: ...4 Troubleshooting Table 10000000584 36 Edition 002 ...