Installation
Pi20
Rev. B 09/2011
23
Figure 11: NTSC Video Output Example
The video output is not used with TSA and DTPi software.
5.8
Ethernet Communication
For connecting the camera to the PC, a dedicated Ethernet connection is required.
Camera IP Address
The factory default IP address for the camera is
192.168.200.254
.
The camera’s address is not free of choice: It has to be unique in the network, meaning that no other
device in the network (including the PC network adapter) may run at the same IP address.
Ask your IT administrator for a free IP address to be used!
Advanced Ethernet Settings
Subnet Mask:
The Subnet Mask defines the interpretation of the IP address. The factory default setting is
255.255.255.0
.
Gateway:
A gateway connects two subnets (which have a different subnet address). The factory default setting is
192.168.200.1
.
5.8.1
Changing the Ethernet Settings for the PC
The network adapter on the PC side can be configured as follows:
(example below is for Windows XP systems)
1.
Go to <Start> <Settings> <Network Connections> <Local Area Connection>
To establish the Ethernet communication, the subnet addresses for both the camera and
the PC need to match! Appropriate changes can be applied either on the camera side or
on the PC network adapter!
Содержание RAYPi20HTMA
Страница 1: ...ThermoViewTM Pi20 Fixed Thermal Imager Operating Instructions Rev B 09 2011 55301 ...
Страница 41: ...Accessories Pi20 Rev B 09 2011 41 Figure 18 Digital Input Wiring Figure 19 Relay Output Wiring ...
Страница 43: ...Accessories Pi20 Rev B 09 2011 43 Figure 20 Analog Output Wiring Figure 21 Digital Output Wiring ...