ASCII Programming
108
MI3
Examples for the head command “Emissivity”:
?2E
requests the emissivity for sensing head at address 2
2E=0.975
sets the emissivity to 0.975 for sensing head at address 2
!2E0.975
sensing head at address 2 confirms the emissivity setting
18.8
Addressing of Multiple Boxes (RS485)
Up to 32 communication boxes can be connected within an RS485 network. To direct a command to
one box among the 32 possible, it is necessary to „address“ a command. Therefore, a 3-digit number is
set prior the box command. The 3-digit number is determined between 001 and 032.
XA=024
will set address to 24 (box must not be in multidrop mode)
Changing an address:
(e.g. the address is changed from 17 to 24)
command
answer
„017?E“
„017E0.950“
„017XA=024“
“017XA024” setting of a new address
„024?E“
„024E0.950“
Note:
A box with the address 000 is a single box and not in multidrop mode.
If a command is transferred, starting with the 3-digit number 000, all boxes (with addresses from 001
to 032) connected will get this command – without to send an answer.
command
answer
“024?E”
“024E0.950”
“000E=0.5”
will be executed from all units, no answer
“024?E”
“024E0.500”
“012?E”
“012E0.500”
18.9
Command Set
P ... Poll, B ... Burst, S ... Set, N ... Notification
n ... head number, v ... value, X ... uppercase letter
Description
Char
Format
P B S N Legal Values
Factory default Head /
Box
Poll parameter
?
?X
√
?T
Set parameter
=
X=…
√
BR=115200
Error message
*
*Syntax error
Acknowledge message !
!BR115200
Burst string format
$
?$ or
$=nT
√
√
TIXJXT
Ambient background
temp. compensation
A
nA
float
√
√
√
°C/°F
23°C
H
Advanced hold with
average
AA
nAA
float
√
√
√
0 – 999.9 s
000.0s
H
Control ambient
background temp.
compensation
AC
nAC
√
√
√
0 – sensor temp.
1 – via number
2 – via ext. input
0
H
1.800.868.7495
Содержание MI3
Страница 2: ...1 800 868 7495 info Raytek Direct ca...
Страница 9: ...20 NOTES 119 1 800 868 7495 info Raytek Direct ca...
Страница 73: ...Accessories MI3 Rev F1 05 2013 73 Figure 66 Protective Window 1 800 868 7495 info Raytek Direct ca...
Страница 113: ...ASCII Programming MI3 Rev F1 05 2013 113 1 800 868 7495 info Raytek Direct ca...
Страница 119: ...Notes MI3 Rev F1 05 2013 119 20 Notes 1 800 868 7495 info Raytek Direct ca...