background image

Quick Start 

Safety Information: 

White

-

Light

,

 

730nm 

and IR Variants (850nm & 940nm) 

Caution – Risk Group 2. Avoid Exposure / use protection.  

See Safety Information in FULL Instruction Guide for details. 

Box Contents:

VARIO2 Illuminator with 35° ILS fitted, spare 60° beam angle ILS, User Guide 

(ILS: Interchangeable Lens  System)  

Optional Accessories:  Remote Controller for additional programming,   

80˚ beam angle ILS, 120˚ beam angle ILS, Bracketry 

Factory Default Set-Up: 

35˚ Beam Angle ILS, Max 100% Power 

Telemetry Input – closed, Photocell sensitivity – MID 

Status LEDs – ON, No PIN Set 

Unit will change from Programming Mode to Operating Mode after 7 Days (or 30 

minutes after last press of manual buttons

)

 

Timer Disabled

VARIO2 Specifications Table:

 

i16 

w16 

  i8 

w8 

i6 

i4 

w4 

  i2 

w2 

Consumption 

100W 

max 

84W 

max 

46W 

max 

42W 

max 

25W 

max 

13W 

max 

24W 

max 

10W 

max 

11W 

max 

Input 

24V AC/DC 

12/24V AC/DC 

12/24V AC/DC 

12/24V AC/DC 

Weight 

3.1kg  (6.8lbs) 

1.65kg (3.61lbs) 

950g  (2.1lbs) 

600g  (1.3lbs) 

Number of 

LED’s 

48 

24 

12 

12 

Environment 

IP66 

IP66 

IP66 

IP66 

Dimensions 

180 x 277 x 75mm 

7”x11”x2.9” 

135 x 180 x 68mm 

(5”x7”x3”) 

100 x 135 x 66m 

4”x5”x2.5”) 

75 x 100 x 64mm 

3”x4”x2.5”) 

Cable Length 

2.5m 

2.5m 

2.5m 

2.5m 

2.5m 

2.5m 

2.5m 

2.5m 

2.5m 

Ver

. 10

/1

9

 

Содержание VARIO2 VAR2-i2-2

Страница 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Страница 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Страница 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Страница 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Страница 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Страница 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Страница 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Страница 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Страница 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Страница 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Страница 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Страница 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Страница 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Страница 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Страница 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Страница 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Страница 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Отзывы: