UK/Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Toll Free: +1 888 505 8335
*Note - If you forget your pin and need to make adjustments to the illuminator(s) you
need to do full Re-set. This requires power recycling whilst pressing the two manual
control buttons at the same time. This will restore factory default settings AND remove
the previously programmed PIN. Both LEDs will flash AMBER to signify that the process
has been completed.
*Note – If you need to check if a PIN is set up, In Operating Mode hold the status
button down for 4 seconds and if both LEDs flash RED, this means there is no PIN
present.
14
Manual Control Buttons
Manual control buttons for each illuminator are accessed by removing the base plate at the bottom of
the unit (2 screws).
The two manual control buttons gives a wide selection of user control :
1.
Power Control – 100%, 80%, 60%, 40%, 20% of maximum. (Factory
Default is 100%)
2.
Photocell Control – 3 levels, 25 Lux on, 50 Lux off, 10 Lux on 30 Lux off,
5 Lux on 15 Lux off and photocell disable.
3.
Turn LED indicators on & off
4.
Illuminator Reset Options
5.
Disable Remote Control and enter Operating Mode or Enable
Remote Control and enter Programming Mode
6.
Button Enable & Disable