System Configuration
The following information details the possible interconnections between lamps and cameras and the
links made using the Configuration Mode DIP Switch. Links that are permanently hard wired are marked
HW. Links that are made by turning ON (closing) switches 1 to 4 are identified by number.
Configurations marked X are not valid.
Selection Options
Element
A
PC Lamp1
A
X
B
PC Lamp2
B
1
X
C
Cam1 IN
C
HW
1
X
D
Cam2 IN
D
1
HW
1
X
E
PC Aux
E
HW
1
HW
1
X
F
Tel Lamp1
F
X
X
X
X
X
X
G
Tel Lamp2
G
2
X
2
X
2
3
X
H
Cam1 OUT
H
X
X
X
X
X
HW
3
X
I
Cam2 OUT
I
2
X
2
X
2
3
HW
3
X
J
Tel Aux
J
X
X
X
X
X
HW
3
HW
3
X
K
Signal Ground
K
X
X
X
X
X
X
4
X
4
X
X
Note : PC=Photocell, Tel=Telemetry, Aux=Auxiliary
Hard Wired Connections
PC Lamp1 is linked to Cam1 IN and PC Aux
PC Lamp2 is linked to Cam2 IN
Cam1 OUT is linked to Tel Lamp1 and Tel Aux
Cam2 OUT is linked to Tel Lamp2
Switch 1 OFF (Default Setting)
No Action
Switch 1 ON
Connects PC Lamp1 to PC Lamp 2
PC Lamp1
or
PC Lamp2 status (day/night) is linked
to Cam1 IN, Cam2 IN and PC Aux
Switch 2 OFF (Default Setting)
No action
Switch 2 ON
Connects Tel Lamp2 and Cam2 OUT to PC
Lamp1, Cam1 IN and PC Aux.
Switch 3 OFF
No Action
Switch 3 ON (Default Setting)
Connects Tel Lamp1 to Tel Lamp2 and links to
Cam1 OUT
or
Cam2 OUT
or
Tel Aux which can
switch both Lamps on (under Photocell control) or
operate lamp timer / dimming modes.
Switch 4 OFF (Default Setting)
No action
Switch 4 ON
Tel Lamp2 and Cam2 OUT is linked Signal Ground.