background image

SPARTAN

Floodlight Range Installation Guide 

Zone 1 variant CML13ATEX3007 or IEC Ex CML14.0001 or CML 21UKEX3099
Zone 2 variant CML17ATEX4231 or IEC Ex CML 17.0135 or CML 21UKEX4106

This installation guide provides instructions for installing the Infra-Red and  
White-Light SPARTAN series of explosion protected floodlights. 
 
Text in 

Bold

 is specific for emergency variants

Overview 

1

 

Safety Instructions 

2

 Installation 

3

 Maintenance 

4

 

Technical  Specification 

5

 

Trouble Shooting

The SPARTAN series of explosion protected floodlights are specialist devices, 

certified for use in specific operating environments. 

The units must be installed in accordance with these instructions, must be correctly 

certified for the specific operating environment and must be installed by suitably 

qualified personnel.

 

Emergency floodlights will require the fuse to be reconnected upon 

installation and the floodlight subjected to three 24 hour charge/discharge 

cycles to bring the battery up to peak capacity.

 

If you have any queries about the installation or the certification of the unit – please 

contact Raytec for immediate assistance and advice.

910-D

-00027 Rev 1

Important information

Содержание SPARTAN 12

Страница 1: ...PARTAN series of explosion protected floodlights are specialist devices certified for use in specific operating environments The units must be installed in accordance with these instructions must be c...

Страница 2: ...ype of threaded cable entry on the luminaire Select suitably certified ATEX IEC Ex UKEX cable glands and stopper plugs these must be parallel thread have a minium of 5 full thread engagement and be of...

Страница 3: ...ing SPARTAN Unit 1 To meet the requirements of certification a MINIMUM of 2 fixing points must be used the fixing points must be suitable for the conditions of use Raytec recommend using M8 Marine Gra...

Страница 4: ...ending on the mounting application where possible the cable glands should be kept to the bottom of the floodlight It is very important that the red fibre washers are fitted between the SPARTAN housing...

Страница 5: ...ww raytecled com UK Europe Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 Typical wiring diagram standard luminaires Typical wiring diagram emergency luminaires WHITE RED WHITE RED WHITE RED WHITE R...

Страница 6: ...k connection 8 Emergency SPARTAN floodlights may have a single green LED fitted adjacent to the incoming cable glands when illuminated the green LED indicates that the emergency system is healthy 9 Th...

Страница 7: ...ons or spare parts will invalidate certification and make the equipment dangerous 3 Isolate the SPARTAN unit from the mains supply and allow to cool before carrying out any maintenance work 4 The unit...

Страница 8: ...Environment Emergency variant N A 11 5kg 25 3lbs 21kg 46 3lbs Dimensions Dimensions See previous pages for line diagrams ATEX and IECEx and UKEX Rating See below CML13ATEX3007 or IEC Ex CML14 0001 or...

Страница 9: ...put is turned on at the source 4 On emergency variants check fuse to ensure it has not blown 5 If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by sw...

Страница 10: ...nt emergency Certification CML Body New Port Road Ellesmere Port CH65 4LZ Certificate Zone 1 CML13ATEX3007 IEC Ex CML14 0001 CML21UKEX3099 Zone 2 CML17ATEX4231 IEC Ex CML17 0135 CML21UKEX4106 ATEX Qua...

Страница 11: ...ty Requirements has been assessed by reference to the following harmonised designated standards EN 60079 0 2018 EN 60079 7 2015 A1 2018 EN 60079 18 2015 A1 2017 EN 60079 31 2014 EN 60079 1 2014 And al...

Страница 12: ...UK Europe T 44 0 1670 520055 F 44 0 1670 819760 hazsales raytecled com Americas Toll Free T 1 888 505 8335 ushazsales raytecled com www raytecled com...

Отзывы: