background image

 

Application Drawing 

RVi1120  120W Power Supply Installation Manual

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

DO NOT REMOVE COVER. NO USER SERVICEABLE

PARTS INSIDE. REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL.

Midspan Connection

The Global Leader in LED Lighting for Security and Saftey            

     

www.rayteccctv.com

Important Safety Warning

- Connect the DC round connector to the input of the RVi2202 

AC Connection

- Read these instructions.

- Keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should 

  conform to all local codes.

- DO NOT bundle UTP signal wires in the same conduit as high-voltage

  wiring.

- To reduce the risk of fire or electrical shock, do not expose these products 

  to rain, moisture, dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on equipment.

- DO NOT install the unit in a place where the operating ambient tempera-

  ture exceeds 75° C.

- Make sure that the external power supply output voltage is in the recom-

  mended range. 

- Do not install near any heat sources such as radiators, heat registers, 

  stoves or other apparatus that produce heat.

- Protect the power cord from being walked on or pinched particularly at 

  plugs, convenience receptacles, and the point where they exit from the 

  apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long 

  periods of time.

- Refer all servicing to qualified service personnel. Servicing is required

  when the apparatus has been damaged in any way, such as a power 

  supply cord or plug is damaged, liquid has been spilled, or objects have

  fallen into the apparatus, the apparatus has been exposed to rain or 

  moisture, does not operate normally, or has been dropped.

- The mains plug is used as the disconnect device and shall remain readily

  operable.

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - This apparatus is a Class I product. This product must 

be connected to a mains socket outlet through an AC to DC Power supply 

when using DC input.
         WARNING! - The mains plug is used as the disconnect device and 

shall remain readily operable. 

Network Switch

RVi1120

RVi2202

Up to 60W PoE and data

VAR-IPPOE-i8-1

VAR-IPPOE-i8-1

The Raytec Model RVi1120 is a universal input AC/DC wall mount power 

supply.  It is designed to work with the most demanding PoE Midspan 

devices for CCTV applications. It can provide up to 120W at 56V.  

It is highy reliable with sevearl internal protection circuits including Short 

Circuit, Overload, Over Volatge and Over Temperature. The RVi1120 is a 

class I power supply with earth pin. It has a buit-in active PFC circuit.

It meets the EISA 2007 Energy Independence and Security Act.

- Plug the  AC power cord provided with the unit to the mains. The Green 

  LED will indicate the power status.

Warning: In order to turn the power supply off unplug the  

AC power cord from the unit and the mains. 

Отзывы: