background image

Catalog No.:  2000.17 

Effective:  6-22-09 

Replaces:  New

 

Job: 

 

           

 

Engineer: 

 

           

 

Contractor: 

 

           

 

Prepared By: 

            

 Date:

             

 

Model:  

         

 

 Indoor/Outdoor:   

         

 

 

Up to 94% Thermal Efficiency at Full Rate 

100% Factory Fire Tested 

Maximum Outlet Water Temperature: 210°F 

Maximum System Temperature: 200°F 

Full Safety Diagnostics with History 

Footprint: Less Than 9-1/2 ft

2

 

Limited Twenty-Year Thermal Shock Warranty 

Limited Ten-Year Heat Exchanger Warranty 

Full Electronic Modulation, Constant Ratio 5:1 Turndown 

Soft-Start Modulating Controller with LCD Display 

Status and Full Diagnostics Display 

 

 

Heat Exchanger 

ƒ

  All Stainless Steel Construction 

ƒ

  Gasketless Heat Exchanger Design 

ƒ

  ASME H Stamped 

160 PSIG Working Pressure 

ƒ

  National Board Approved 

ƒ

  ASME Pressure Relief Valve 

 60 PSIG – Standard  
        PSIG – Optional  

ƒ

  Temperature and Pressure Gauge, 

Shipped Loose 

Control 

ƒ

  120V, 60Hz, 1Ø, Power Supply 

ƒ

  Digital Operating Control with LCD 

display. 

ƒ

  Outdoor reset with Indirect Priority 

ƒ

  0-10 VDC input for BMS 

ƒ

  Cascade up to 8 boilers 

ƒ

  Spark Ignition (IID) 

ƒ

  Remote Flame Sensor 

ƒ

  High Limit, Manual Reset, Fixed, 

200ºF 

ƒ

  Auto Limit, Fixed, 210ºF 

ƒ

  Alarm Dry Contact Connection 

ƒ

  On/Off Power Switch 

ƒ

 Flow Switch 

ƒ

  Blocked Vent Pressure Switch 

ƒ

  Boiler, DHW & System Pump 

Contacts 

ƒ

  Water Temperature Sensors (3) 

Burner 

ƒ

  Ultra-Low NOx: Less than 20 PPM 

 

 

 

Gas Train  

ƒ

 Fuel 

 Natural Gas 
 Propane 

ƒ

 Zero Governor Regulator 

ƒ

  Dual-Seat Combination Valve 

ƒ

  Electronic Modulating Firing Mode (H7)  

Construction 

ƒ

 Indoor/Outdoor Construction 

ƒ

 Front Controls Enclosed 

ƒ

  PolyTuf Powder Coat Finish 

ƒ

  Rear Connections (Electrical, Gas, Vent, 

Combustion Air) 

ƒ

  Top Connections (Water) 

ƒ

  Design Certified ANSI Z21.13/ 

CSA 4.9 

Venting (PVC-CPVC-Stainless.) 

ƒ

 Vent Termination 

 Indoor, Vertical – Option D-11 
 Indoor, Horizontal – Option D-15 
 Outdoor 

ƒ

  Extractor - Optional 

 By others 
 Not required 

 

Multi-Boiler System Controllers 

 B-36  TempTracker Mod+ Digital 

Controller, 2-4 Boilers, OA Reset 

 B-37  TempTracker Mod+ Digital 

Controller, 5-10 Boilers, OA Reset 

 B-38   TempTracker Mod+ Digital 

Controller, 11-16 Boilers, OA Reset 

Options 

 D-21   TruSeal™ Combustion Air Inlet  
 P-      Pump:           HP, 120V, 1

, 60Hz 

 

 Cast Iron 

 Bronze 

 S-1 

Low Gas Pressure Switch,  
Manual Reset 

 S-2 

High Gas Pressure Switch, 
Manual Reset 

 Z-12  Condensate Neutralizer Kit 

 

Regulatory Agency Requirements 

  

 

 

 
 
 

XFyre™

 

- Type H

   Condensing Heating Boilers

Models 300-850

 

Отзывы: