Raypak VERMONT RFSDV34RFNAU Скачать руководство пользователя страница 1

 
 

 

 
 
 

RAYPAK VERMONT RFSDV34 

FREESTANDING GAS LOG FIRE 

 
 

 

 
 
 
 

 

Installation and Operating Instructions 

 
 

For Models RFSDV34RFNAU (Natural Gas) & 

RFSDV34RFPAU (Propane)

Page 1 of 27 

Содержание VERMONT RFSDV34RFNAU

Страница 1: ...RAYPAK VERMONT RFSDV34 FREESTANDING GAS LOG FIRE Installation and Operating Instructions For Models RFSDV34RFNAU Natural Gas RFSDV34RFPAU Propane Page 1 of 27 ...

Страница 2: ...nces General Information for Assembling Vent Pipes Vertical Through Roof Applications Install Vertical Venting Part 4 Operating Instructions General Glass Information Window Frame Assembly Removal Glass Cleaning Log Set and Lava Rock Installation Maintenance Flame and Temperature Adjustment Flame Appearance Remote Control Options RFSDV34 Lighting Instructions Part 5 Troubleshooting Troubleshooting...

Страница 3: ...Part 7 Conversion Gas Type Conversion Instruction Part 8 Wiring Diagram Wiring Diagram Part 9 Warranty Page 3 of 27 ...

Страница 4: ...ppliance DO NOT touch any electrical switch Turn off gas supply at the meter Immediately call Rheem Service your gas supplier or licensed gasfitter Note Some gases are heavier than air and it maybe necessary to check for gas leaks at floor level CAUTION DO NOT operate this appliance before reading this instruction booklet DO NOT place articles or objects on or against the appliance DO NOT store ch...

Страница 5: ...nd air passages in this fireplace should be kept clean and free of dust and lint Make sure that the gas valve and pilot light are turned off before you attempt to clean this appliance 7 The flueing system should be checked once a year and cleaned if required 8 Keep the area surrounding this appliance clear of combustible materials gasoline and other flammable vapour and liquids This heater should ...

Страница 6: ...or at least 10 hours the first time you use it Please turn the fan switch in the OFF position during this initial firing Fig 1 Locating Your Gas Fireplace A Flat on wall B Room divider C Island D Cross corner E Flat on wall corner Warning There is a minimum vertical rise required for the venting which varies depending on the application The maximum horizontal run also has restrictions Before start...

Страница 7: ...DIMENSION RFSDV34 A 667mm B 800mm C 492mm D 762mm E 254mm F 394mm G 114mm H 667mm I 333mm J 495mm K 162mm Page 7 of 27 ...

Страница 8: ...flue and electrical supply On completion of the installation ensure that the appliance is commissioned and tested Fitting Line Installation Warning When purging the fitting line the front glass must be removed Note For pipe sizing requirements refer to Australian Standard AS5601 Gas Installations If gas fitting line has been previously completed check that the gas fitting line is of adequate size ...

Страница 9: ...tening the gas inlet pipe compression nut For Propane installations an approved gas regulator must be fitted in accordance with AS5601 Ensure copper tube meets the requirements of Australian Standard AS1432 Type B Note Heater must be tested for correct operation by the installer after installation is complete Page 9 of 27 ...

Страница 10: ...allation with a maximum flue height of 12m and a minimum flue height of 3m Suspend a plumbline from the ceiling to the centre of the flue spigot Mark the centre of the flue spigot on the ceiling Prior to cutting the ceiling ensure that there is at lease 25mm clearance from any combustible materials Fit ceiling ring flue and flue cover Page 10 of 27 ...

Страница 11: ...iance to be operated without the front glass or with a broken glass Replacement of the glass including the gasket as supplied by Raypak Australia should be done by a licensed and qualified service person Window Frame Assembly Removal 1 Shut off gas see lighting instructions 2 If the unit has been operating let it cool 3 Open the two side doors 4 Open the clamps on the two sides Fig 2 5 Pull the fr...

Страница 12: ... the unit so it will not move from side to side and is firmly positioned on the bracket 4 Slip front ember log KR7 down behind the front deflector 5 Place front left log KR8 on top of burner left side Using the bottom holes in the log locate it into the left bracket log locator studs 6 Place front right log KR9 on top of burner right side Use the log s bottoms holes to locate it into the right bra...

Страница 13: ...appear to be abnormal place a service call Fig 4 DVT pilot flame Fig 5 RFSDV34 flames Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This heater has a pilot which must be lit manually To light the pilot follow these instructions exactly B BEFO...

Страница 14: ...l knob slightly and turn it clockwise to the off position Do not force knob 6 Wait 5 minutes to allow any gas to clear Then smell for gas including near the floor If you smell gas STOP and follow step B in the safety information above If you do not smell gas go to the next step 7 Remove the glass door before lighting the pilot See Glass Removal Section page 10 8 Visibly locate pilot next to the ma...

Страница 15: ...ay from grounded metal Operation 1 If the manual switch is in the REMOTE position switch it to LOCAL 2 Turn the pilotstat knob anticlockwise from the OFF to the PILOT position push the knob down and hold it in position The pilot valve is now open and allows gas to flow to the pilot burner 3 Push the plunger on the piezo ignitor until the pilot burner is lit When the pilot burner is lit the LED on ...

Страница 16: ...burner or fan To shut off the system turn the pilotstat knob clockwise to the OFF position This action closes the main gas and safety valves The remote control cannot turn on the main burner or fan Remote Control Operation Refer to Fig 7 OFF Mode In the OFF mode the fireplace flame and fan are off the display will show OFF and display the room temperature If the receiver is in the REMOTE mode the ...

Страница 17: ... press the UP or DOWN key Each key press changes the setting by one degree In the AUTO mode the fan speed increases with increased fan height and decreases with the decreased fan height AUTO is displayed next to the flame and fan icons Fan Override During Auto Mode If a higher or lower fan speed is desired when operating in AUTO mode override the fan speed by pressing the fan button then the Up or...

Страница 18: ...ink after every valid command received from the remote control this is not an error 3 Failure codes may occur anytime after the pilot burner is lit 4 The sequence is failure code followed by light not blinking for 30 seconds 5 In the event of multiple failure codes the next failure code follows previous failure code by approximately 3 seconds If an error code 3 is observed while performing the tes...

Страница 19: ...or code 8 while in the REMOTE mode the valve is defective and should be replaced If the valve is producing error code 8 while in the LOCAL mode go to the next step 2 Slide the REMOTE LOCAL switch to REMOTE and program the remote control as per item 6 page 13 The error code will clear itself after approximately 1 5 minutes and return to normal operation Page 19 of 27 ...

Страница 20: ...below room temperature on the remote control does the main valve and fan turn off Turn pilotstat knob to OFF to turn valve completely off No No Five minute wait period Set manual switch to local or remote Light pilot burner Did the LED stop blinking Release pilotstat knob Turn pilotstat knob from PILOT to ON Cycle switch once and leave in remote Press any key on the Remote Control for recognition ...

Страница 21: ...ctor which must be replaced with the pilot injector provided in the conversion kit 9 Honeywell Gas Valve The Honeywell valve fitted to this appliance is preset for Propane gas It is convertible to natural gas by a colour coded conversion screw To insert the conversion screw refer to the instructions and diagrams in the Honeywell Installation Instructions supplied in the conversion kit packaged wit...

Страница 22: ...rt 8 Wiring Diagram A N 240V AC Terminal Block Transformer 240V AC 110VAC 2A 50VA Fuse 3 Amp 240V AC 50 Hz Main Heater Supply Speed Control High Limit Fan RFSDV34 GAS LOG FIRE WIRING DIAGRAM Page 22 of 27 ...

Страница 23: ...Page 23 of 27 ...

Страница 24: ...Page 24 of 27 ...

Страница 25: ...Page 25 of 27 ...

Страница 26: ...e heat exchanger for 10 years pro rata with a 1 year labour warranty Notes Rheem Australia Pty Ltd provides warranty service and spare parts on behalf of Raypak Australia Pty Ltd Refer to item 5 of warranty conditions Rheem reserves the right to transfer fully functional components from the defective gas log fire to the replacement appliance if required In addition to this warranty the Trade Pract...

Страница 27: ...ce is installed 4 Where a failed component or appliance is replaced under warranty the balance of the original warranty period will remain effective The replaced part of appliance does not carry a new warranty 5 Where the gas log fire is installed outside the boundaries of the metropolitan area as defined by Rheem or further than 25 km from a regional Rheem branch office or an accredited service a...