background image

Catalog No.:  2000.364A 

Effective:   8-15-07 

Replaces:  6-15-07

 

Job: 

 

           

 

Engineer: 

 

           

 

Contractor: 

 

           

 

Prepared By: 

            

 Date:

             

 

Model:  

         

 

 Indoor/Outdoor:   

         

 

 

84% Thermal Efficiency at Full Rate 

100% Factory Fire Tested  

Maximum Outlet Water Temperature: 220°F 

Minimum Acceptable Inlet Water Temperature: 120°F 

Full Safety Diagnostics with History 

Footprint: Less Than 5-1/2 ft

2

 

Limited Twenty-Year Thermal Shock Warranty 

Limited Ten-Year Heat Exchanger Warranty 

Electronic Modulation, Constant Ratio 1.4:1 Turndown 

TempTracker Mod Controller with LCD Display 

Status Display Lights 

 

 

Heat Exchanger 

ƒ

  Bronze Headers   

ƒ

  ASME H Stamped 

160 PSIG Working Pressure 

ƒ

  National Board Approved 

ƒ

 Fin Tubing 

 Copper – Standard  
 Cupro Nickel – Option A-3 

ƒ

  ASME Powder-Coated Tube Sheet 

ƒ

  Silicone High Temp O-Rings 

ƒ

  ASME Pressure Relief Valve 

 60 PSIG – Standard  
        PSIG – Optional  

ƒ

  Temperature and Pressure Gauge, 

Shipped Loose 

ƒ

  Stainless Steel Evaporator Plate 

Control 

ƒ

  120V, 60Hz, 1Ø, Power Supply 

ƒ

  120/24V 60Hz Transformer 

ƒ

 Ignition Module 

 3-Try – Standard 
 Single-Try – Option C-6 

ƒ

  Hot Surface Ignition (HSI) 

ƒ

  Remote Flame Sensor 

ƒ

  High Limit, Manual Reset, Fixed, 

240ºF 

ƒ

  On/Off Power Switch 

ƒ

 Flow Switch 

ƒ

  Blocked Vent Pressure Switch 

ƒ

  Combustion Air Proving Switch 

ƒ

 Pump Switch 

ƒ

  Pump Time Delay 

ƒ

 Diagnostics Panel 

ƒ

  Modulating Temperature Control 

ƒ

  Water Temperature Sensors (3) 

Burner 

ƒ

  Ultra-Low NOx: Less than 20 PPM 

Gas Train  

ƒ

 Fuel 

 Natural Gas 
 Propane 

ƒ

 Zero Governor Regulator 

ƒ

  Dual-Seat Combination Valve 

ƒ

  Electronic Modulating Firing Mode  

Construction 

ƒ

 Indoor/Outdoor Construction 

ƒ

 Front Controls Enclosed 

ƒ

  PolyTuf Powder Coat Finish 

ƒ

  Rear Connections (Water, Electrical, 

Gas, Vent, Combustion Air) 

ƒ

  Design Certified ANSI Z21.13/ 

CSA 4.9 

Venting 

ƒ

  Vent Termination Cap 

 Outdoor - Option D-11 
 Indoor, Horizontal – Option D-15 
 Indoor, Vertical (by others) 

ƒ

 Combustion Air 

 In-Line Filter Kit – Option D-17 
 Air Intake Elbow – Option D-16 

ƒ

  Extractor – Optional  

 By others 
 Not required 

 
 

Temperature Controllers 

 B-36  Temp-Tracker Mod+ Digital 

Controller, Up to 4 Boilers,  
OA Reset 

 B-37  Temp-Tracker Mod+ Digital 

Controller, Up to 10 Boilers,  
OA Reset 

 B-38   Temp-Tracker Mod+ Digital 

Controller, Up to 16 Boilers,  
OA Reset 

 Y-241  Electronic Sequencer, 

Up to 4 Boilers  

 Y-281  Electronic Sequencer, 

Up to 8 Boilers 

Options 

 A-13  Air Vent, Auto, 150 PSI 
 F-10  Low Water Cut-Off, Remote Probe 
 I-1 

High Limit, Auto Reset, Adj.,  
100-240

°

 I-2 

High Limit, Manual Reset, Adj., 
100-240

°

 P-      Pump:           HP, 120V, 1

, 60Hz 

 

Water Hardness:              GPG  

 

 Cast Iron 

 Bronze 

 

 Loose 

 Mounted 

 P-      Cold Water Start 
 P-      Cold Water Run 
 S-1 

Low Gas Pressure Switch,  
Manual Reset 

 S-2 

High Gas Pressure Switch, 
Manual Reset 

Regulatory Agency Requirements 

            

 

MVB™ - Type H

    Heating/Hot Water Supply Boilers 

Models H7 504-2004