On/Off Models Only
Parameter
Crosswind On/Off Models
40-O
50-O
65-O
Heating capacity (Btu)
40000 BTU
50000 BTU
65000 BTU
Heating current: Air 80°F (27°C), Water 80°F (27°C)
7.7A
10.8A
Heating power: Air 80°F (27°C), Water 80°F (27°C)
1.65 KW
2.3 KW
Heating current: Air 80°F (27°C), Water 95°F (35°C)
9.6A
13.2A
Heating power: Air 80°F (27°C), Water 95°F (35°C)
2.0 KW
2.7 KW
Compressor RLA/LRA
9.7A/20A
11.6A/60.2A
Fan motor rating
0.5 A
0.5 A
Design pressure (High)
≤609 PSIG
≤609 PSIG
Design pressure (Low)
≤261 PSIG
≤261 PSIG
Refrigerant (R410A)
44.1 oz
60 oz
Net weight
4056 oz
4303 oz
Power supply
208-230VAC/ 1 Ph/60Hz
Water circulation flow
67-100 L/min
83-116 L/min
Noise
≤50 dB(A)
≤58dB(A)
Waterproof class
IPX4
IPX4
Table K. Technical Parameters - On/Off Models Only
10. REPLACEMENT PARTS
NOTE:
To supply you with the correct part, it is important
that you supply the heater model number, serial number
and type of gas when applicable.
Any part returned for replacement under standard
company warranties must be properly tagged with a
return parts tag, completely filled in with the heater serial
number, model number, etc., and shipped to the Company
freight prepaid. If determined defective by the Company
and within warranty, a like part or equal substitution will be
returned, freight collect. Credit will not be issued.
MANUFACTURER:
2151 Eastman Avenue
Oxnard, Ca 93030
1-800-260-2758
6100.64_Crosswind.indd 23