Raypak 751-1501 Скачать руководство пользователя страница 1

Catalog No.:  2000.36G 

Effective:  2-1-08  

Replaces:  5-1-05

 

Job: 

 

           

 

Engineer: 

 

           

 

Contractor: 

 

           

 

Prepared By: 

            

 Date:

             

 

Model:  

         

 

 Indoor/Outdoor:   

         

 

   

 

 

100% Factory Fire Tested  

Efficiency: 84% 

Maximum Outlet Temperature: 230°F 

Minimum Non-Condensing Inlet Temperature: 105°F 

Thermal Shock Proof Heat Exchanger 

Footprint: Less Than 5-1/2 ft

2

 

Limited Twenty-Year Thermal Shock Warranty 

Limited Ten-Year Heat Exchanger Warranty 

Ten-Year Unconditional Burner Head Warranty 

Operation Status Center and Full Diagnostic Panel 

 

 

Heat Exchanger 

ƒ

  Bronze Headers   

ƒ

  ASME Inspected and Stamped 

160 PSIG Working Pressure 

ƒ

  National Board Approved 

ƒ

 Copper-finned Tubes 

ƒ

  ASME Steel Tube Retainer 

ƒ

  Silicone High Temp O-Rings 

ƒ

  60 PSIG ASME Pressure Relief 

Valve 

ƒ

  Temperature and Pressure Gauge, 

Shipped Loose 

Control 

ƒ

  120V, 60Hz, Power Supply 

ƒ

  120/24V 60Hz Transformer 

ƒ

  100% Pilot Shutoff/Lockout 

ƒ

  Electronic Intermittent Ignition Pilot 

(IID) 

ƒ

  High Limit Control, Manual Reset 

ƒ

  High Limit Control, Auto Reset 

ƒ

 On/Off Switch 

ƒ

 Flow Switch 

ƒ

  Blocked Vent Pressure Switch 

ƒ

  Combustion Air Proving Switch 

ƒ

  Time Delay Pump Off Control 

 

ƒ

  Central Point Wiring Diagnostics 

Panel 

Burner 

ƒ

 Aerodynamically Stabilized 

Non-Clog  Burner  

ƒ

  Ultra-Low NOx: Less than 30 PPM 

Gas Train  

ƒ

 Fuel 

 Natural Gas 
 Propane (Models 751 & 1001) 

ƒ

  Manual Gas Shut-off Valves 

ƒ

 Gas Pressure Regulator 

ƒ

  Safety Shut-off Valve 

ƒ

 Firing Control Valve 

ƒ

  Manual Low Gas Pressure Switch 

ƒ

  On/Off Firing Mode (H4) 

ƒ

  Design Certified ANSI Z21.13/ 

CSA 4.9 

Construction 

ƒ

 Indoor/Outdoor Construction 

ƒ

 Front Controls Enclosed 

ƒ

  PolyTuf Powder Coat Finish 

ƒ

  Connections (Water, Electrical, 

Gas) 

 Rear – Standard 
 Right Side – Option A-8 

Venting 

ƒ

 Vent Location 

 Rear – Standard  
 Right Side – Option Z-2 

ƒ

  Vent Termination Cap 

 Outdoor - Option D-11 
 Indoor, Horizontal – Option D-15 
 Indoor, Vertical (by others) 

Temperature Controls 

 B-20 

Single-Stage Controller,  
100-200°F 

 B-6 

2-Stage Controller, 100-200°F 

 B-21 

4-Stage TempTracker Digital 
Controller, Loose 

 B-23 

4-Stage TempTracker Digital 
Controller, Outdoor Reset, Loose 

 Y-241  Electronic Sequencer,  

1-4 Stages 

 Y-281  Electronic Sequencer,  

5-8 Stages 

Additional Safety Controls (Optional) 

 F-10 

Low Water Cut-off,  
Remote Probe 

 S-2 

Manual High Gas Pressure 
Switch 

                        

 

                        

 

Regulatory Agency Requirements 

 C-5 

Ignition Lockout Module 

                        

 

Other Equipment 

 Condensing Heat Exchanger 
 

Pump    

 
 
 

 

 

 

ADB™ - Type H

Hydronic Heating Boilers

Models 751-1501

Отзывы: