background image

RAYN Installation Guide

Rosa 600 Luminaire

RAYN Grow ing Syste ms

| Middleton, WI | +1 844 907 RAYN

© 2021 RAYN Growing Systems, LLC. | All Rights Reserved.
Trademark and patent info: 

rayngrowingsystems.com/ip

| All product

information and specifications subject to change. | RAYN Growing
Systems intends this document to be provided in its entirety.

7430M2100

Rev A Released 2021–04

r a y n g r o w i n g s y s t e m s . c o m

Overview

The Rosa 600 luminaire provides high-intensity LED illumination for plant
science and horticultural research.

A Rosa 600 luminaire may be fitted with standard or customized arrays of
LED emitters depending on the particular growing requirements of the
installation. More details may be found at

rayngrowingsystems.com

.

Accessories

Depending on the luminaire model ordered, the unit may include either
secondary diffusion optics or reflectors pre-installed at shipment. Optical
properties can be altered with field-swappable accessories.

Description

Part Number

Narrow Reflector (~20 degrees)

OP2121

Medium Reflector (~30 degrees)

OP2122

Wide Reflector (~50 degrees)

OP2123

Extra Wide Reflector (~91 degrees)

OP2128

Color Mixing Sub Lens*

OP2114

Acrylic Kit**

7430K1006

C-clamp (for pipe mounting)

7060A2009

DMX Termination Plug

SGE1507

*Requires a corresponding reflector per sub lens.
**Acrylic Kit includes a set of two front lenses.

Содержание Rosa 600

Страница 1: ...standard or customized arrays of LED emitters depending on the particular growing requirements of the installation More details may be found at rayngrowingsystems com Accessories Depending on the luminaire model ordered the unit may include either secondary diffusion optics or reflectors pre installed at shipment Optical properties can be altered with field swappable accessories Description Part N...

Страница 2: ...er la source de lumière lorsqu elle fonctionne Caution Risk Group 2 Possibly hazardous optical radiation emitted from this product Do not stare at operating lamp May be harmful to the eyes Attention Rayonnement optique potentiellement dangereux émis par ce produit Ne regardez pas la lampe en fonctionnement Peut être nocif pour les yeux This product should not be discarded as unsorted waste but mus...

Страница 3: ... operation at 25 C 77 F ambient 36 C 97 F External Temperature steady state achieved at 25 C 77 F 67 C 153 F Operates in relative humidity of 0 90 non condensing non corrosive Note Where dewing is anticipated please contact RAYN Growing Systems about heating and ventilation mitigation Mounting The installation location and mounting hardware must support the weight of the luminaire all cables and a...

Страница 4: ... t nut hardware 422 mm 16 6 in 454 mm 17 9 in 227 mm 8 94 in 31 75 mm 1 25 in 188 mm 7 4 in A A B B B A Ø 11 9 mm 0 47 in B Ø 12 7 mm 0 5 in Weights and Dimensions The noted weights and dimensions are for the luminaire only Weight 15 8 kg 34 9 lbs Dimensions 533x280x235 mm 21x11x9 23 in Rosa 600 Luminaire Page 4 of 12 RAYN Growing Systems ...

Страница 5: ...aire is provided with a 3 m 10 ft power input cable with bare ends A suitably instructed person electrically or electrician must install a compatible connector See Electrical above Custom pre fitted connectors are available Contact RAYN Growing Systems for ordering details Wire Color Code International Standard Wire Color Code North American Standard Connection Type Terminal Green Yellow Green Ear...

Страница 6: ... Use 1 2 3 4 5 Push 1 2 3 4 5 1 Common shield 2 Data 3 Data 4 not connected 5 not connected Terminate DMX 512 The last luminaire in the DMX control run must be terminated to prevent signal reflections Signal reflections cause noise on the data line resulting in corrupted data between the control source and the luminaire This can result in random flashing of the luminaires on that control run To te...

Страница 7: ... wiring verify that the main breaker is in the off position and follow the proper lockout tag out procedures per NFPA Standard 70E or local requirements AVERTISSEMENT Risque de décharge électrique Cette appareil utilise une dangereuse tension et ne doit être installé que par un personne qualifiée en électricité Suivez tous les codes locaux pour l installation Avant de raccorder le câblage d alimen...

Страница 8: ...d that you also secure it in place using a secondary safety cable not provided 3 Make DMX connections See Wiring on page 5 for details a Connect the DMX input cable to the DMX In XLR receptacle b If you are continuing the data run to the next luminaire connect a patch cable to the DMX Thru XLR If you are not continuing the data run terminate DMX at the luminaire See Terminate DMX 512 on page 6 4 P...

Страница 9: ...behind the removable panel on the end of the luminaire Increment and Decrement User interface display Future use Future use Access the user interface to set the DMX start address of the luminaire After five seconds of inactivity when DMX is present the display turns off The display will blink the DMX address when no DMX is present The DMX start address of the luminaire can also be set remotely via...

Страница 10: ...osa 600 luminaire ships from the factory labeled with the luminaire array type which is a three digit alphanumeric code that is formatted similarly to R3a R3e etc This luminaire array type is required when setting up the luminaire for control by the RAYN Touch Controller A B A location of UL luminiare array type label B location of CE luminiare array type label When using the luminaire with a cont...

Страница 11: ... the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear CBL Screen toggles between CBL and ERR to indicate that a control card or the internal cabling is damaged or unplugged No App Screen toggles between no and APP to indicate that the upgraded fixtures have a software issue Use UpdaterAtor softw...

Страница 12: ...RAYN Installation Guide Rosa 600 Luminaire Rosa 600 Luminaire Page 12 of 12 RAYN Growing Systems ...

Отзывы: