SeaNet-Alarm Users Manual

 

The command buttons

 

Icon

Function
Save port settings. If port settings are saved, the programme will load and use 
this settings at the next programme start automatically.

Manually load previously saved port settings.

Connect config programme to SeaNet-Alarm

Disconnect config programme from SeaNet-Alarm 

Open configuration window. 

Toggle logging of raw SeaTalk data

Logging / Status window

The main window shows all 
commands sent to and 
received from SeaNet-Alarm.

SeaNet-Alarm V1.0 

Page 10 of 19

Содержание SeaNet-Alarm

Страница 1: ...aNet Alarm USB Installation and Operation Manual Hardware Version V 1 1 Software Version 1 00 March 2009 2004 All Rights Reserved http www gadgetPool de 2004 Alle Rechte vorbehalten alarm gadgetPool d...

Страница 2: ...9 CONFIGURATION SOFTWARE 9 Port settings 9 The command buttons 10 Logging Status window 10 Port Status 11 Configuration window 12 Alarm Types 13 Delay 13 Duration 14 Status 14 Parameter 14 LED 14 Beep...

Страница 3: ...r and of any connected device are possible at any time The protocol converter could cause damage to connected devices Liability cannot be accepted for any damages personal injuries or malfunctions of...

Страница 4: ...Powers supply and alarm power independent from SeaTalk network Configuration via USB connection to PC and configuration software SeaTalk Instruments are normally installed in the cockpit or wheelhous...

Страница 5: ...SeaTalk network failure internally generated Shallow water alarm from depth instrument Anchor alarm from depth instrument Transducer defective from depth instrument High low windspeed alarm from wind...

Страница 6: ...14 An alarm will be retriggered if the appropriate alarm is reset on the SeaTalk Bus and later set again If an alarm stays active on the seatalk bus and the alarm output is switched off by the acknowl...

Страница 7: ...cted to SeaTalk Network Power Supply Alarm Power supply SeaNet Alarm requires a 12 Volt power supply This power supply is isolated from the SeaTalk network This galvanic isolation protects the SeaTalk...

Страница 8: ...tage and overload protection and current limitation Nominal maximum alarm current 3 5 A Alarm current will be limited to 7 0 A The Alarm output is a Low Side Switch Make sure to have the alarm horn la...

Страница 9: ...driver subdirectory on the CD for the driver installation manual Configuration software The configuration software does not require any installation procedure It consists of just one programme file U...

Страница 10: ...e next programme start automatically Manually load previously saved port settings Connect config programme to SeaNet Alarm Disconnect config programme from SeaNet Alarm Open configuration window Toggl...

Страница 11: ...ill transferred to the PC and printed on the screen This causes a lot of normaly unnecessary data communication In normal SeaNet Alarm operating mode it could even cause loss of an alarm Use this func...

Страница 12: ...et Alarm the configuration window will be activated by pressing Main config Window The software will read the current setting from SeaNet Alarm Changes in the settings are sent to SeaNet Alarm by pres...

Страница 13: ...instrument activated it s High Windangle or it s Low Windangle alarm true or apparent windangle Transducer This alarm will trigger when the depth instrument activated it s Transducer defective alarm...

Страница 14: ...e until the operator presses the acknowledge pushbutton or the alarm is cleared by the SeaTalk device that triggered it Status Function Enable or disable an alarm Select Enabaled or Disabled An alarm...

Страница 15: ...ith this function it can be heard which alarm has been activated The number entered here is the number ob beep s for this alarm Example Beeps set to 3 The Alarm will sound 3 times for one second after...

Страница 16: ...an check the boat and the cruising environment During daytime this function might not be needed It can be switched off without having to have the computer connected Press the pushbutton for more than...

Страница 17: ...et Alarm is switched on it will run in hardware test mode for 10 seconds During hardware test mode the led s will be switched on one after the other When the pushbutton is pressed the alarm output wil...

Страница 18: ...C using USB Port Open a terminal programme i e hypertern and set it to 4800 Baud 8 Bit no parity no handshake Type xxx and press ENTER The device responds with xxx If you receive the xxx connection to...

Страница 19: ...page http www gadgetPool de or you can send mail to alarm gadgetPool de Technical Data Power input 9 15 Volt DC Current draw 16 8 mA all LED s off 1 2 mA per LED Maximum switched current 3 5 A 11 15...

Отзывы: