Once the Micronet system has been installed on the vessel and Auto
Networking has been completed it is necessary to carry out Calibration.
It is not safe to use the displays for navigational purposes until
Calibration has been carried out correctly.
4.1
Depth Offset
The default depth offset is 0.0 making the display read the depth below
the transducer. By adding a +ve or -ve offset the display will show the
waterline depth or depth below the keel respectively.
To enter a depth offset:
Press and hold the
button for 2 seconds to enter Setup.
Press the
button repeatedly to scroll to the Sensors chapter.
Press the
button to enter the sensors menu.
Press the
button repeatedly to scroll to the Depth page.
Press the
button to advance to the Keel/Waterline Offset parameter.
Press the
button to enter Edit Mode, the parameter
value will flash.
Press the
and
buttons to change the value.
Press the
button to exit Edit Mode.
Press and hold the
button to exit Setup and return to normal
operation.