background image

In-line fuse and thermal breaker ratings

The SeaTalkng ® network’s power supply requires an in-line fuse or thermal breaker to be fitted.

In-line fuse rating

Thermal breaker rating

5 A

3 A (if only connecting one device)

Note:

The suitable fuse rating for the thermal breaker is dependent on the number of devices you are
connecting. If in doubt consult an authorized Raymarine dealer.

SeaTalkng ® system loading

The maximum loading / LEN for a SeaTalkng ® system depends on the length of the backbone.

Loading type

Backbone length

Total LEN

Unbalanced

20 m (66 ft)

40

Unbalanced

40 m (131 ft)

20

Unbalanced

60 m (197 ft)

14

Balanced

60 m (197 ft) or less

100

Balanced

80 m (262 ft)

84

Balanced

100 m (328 ft)

60

Balanced

120 m (394 ft)

50

Balanced

140 m to 160 m (459 ft to 525 ft) 40

Balanced

180 m to 200 m (591 ft to 656 ft) 32

Power distribution — SeaTalkng ®

Recommendations and best practice.

• Only use approved SeaTalkng ® power cables. Do NOT use a power cable designed for, or

supplied with, a different product.

• See below for more information on implementation for some common power distribution scenarios.

Important:

When planning and wiring, take into consideration other products in your system, some of which
(e.g. sonar modules) may place large power demand peaks on the vessel’s electrical system.

Note:

The information provided below is for guidance only, to help protect your product. It covers
common vessel power arrangements, but does NOT cover every scenario. If you are unsure how
to provide the correct level of protection, please consult an authorized Raymarine dealer or a
suitably qualified professional marine electrician.

Implementation — direct connection to battery

• SeaTalkng ® power cables may be connected directly to the vessel's battery, via a suitably rated

fuse or breaker.

• You MUST fit a suitably rated fuse or breaker between the red wire and the battery’s positive

terminal.

• Refer to the inline fuse ratings provided in the product’s documentation.

• If you need to extend the length of the power cable, ensure you use suitably rated cable and that

sufficient power (12 V dc) is available at the SeaTalkng ® backbone’s power connection.

36

Содержание Micro-Talk E70361

Страница 1: ...2015 Raymarine UK Limited 87265 2 Document number 04 2017 Date English en US INSTALLATION INSTRUCTIONS Micro Talk Gateway...

Страница 2: ......

Страница 3: ...ts design patents patents pending or design patents pending Fair Use Statement You may print no more than three copies of this manual for your own use You may not make any further copies or distribute...

Страница 4: ......

Страница 5: ...ion instructions 16 User manuals Print Shop 16 2 2 Product overview 17 Multiple data sources MDS 18 SeaTalkng 18 Micronet 18 2 3 Networking restrictions 19 Chapter 3 Planning the installation 21 3 1 I...

Страница 6: ...the Riser 50 5 6 Releasing the unit from the adaptor 52 Chapter 6 System operation and setup 53 6 1 Transducer calibration 54 6 2 Autonetworking 55 Autonetworking compatible Micronet displays 55 Perf...

Страница 7: ...11 2 SeaTalk ng cabling components 77 11 3 SeaTalk ng cables and accessories 78 Appendix A NMEA 2000 PGN support 81 7...

Страница 8: ...8...

Страница 9: ...ply greater than the specified maximum rating may cause permanent damage to the unit Refer to the Technical specification section for voltage rating Caution Power supply protection When installing thi...

Страница 10: ...ipment Requirement for ferrites on non Raymarine cables If your Raymarine equipment is to be connected to other equipment using a cable not supplied by Raymarine a suppression ferrite MUST always be a...

Страница 11: ...issions it may contain In addition our policy of continuous product improvement may change specifications without notice As a result Raymarine cannot accept liability for any differences between the p...

Страница 12: ...12...

Страница 13: ...hapter 2 Document and product information Chapter contents 2 1 Document information on page 14 2 2 Product overview on page 17 2 3 Networking restrictions on page 19 Document and product information 1...

Страница 14: ...tated in this document However the core supplied product and its features will remain the same as those described in this document To ensure that you are using the correct documentation for your produ...

Страница 15: ...y E70327 SeaTalkng power cable A06049 SeaTalkng backbone cable A06036 SeaTalkng 5 way block A06064 SeaTalkng terminator A06031 SeaTalkng T piece A06028 Advanced sailing kit T70342 T70349 Micro Talk E7...

Страница 16: ...mentation that accompanies your display User manuals Print Shop Raymarine provides a Print Shop service enabling you to purchase a high quality professionally printed manual for your Raymarine product...

Страница 17: ...eaTalkng to Micronet Pole Rail or Surface or Bracket mountable using optional mounting kits NMEA 2000 compliant Low power consumption 12 V dc operation 24V protection Waterproof to IPx6 and IPx7 The f...

Страница 18: ...which compatible equipment connect using a spur Data and power are carried within the backbone Devices that have a low draw can be powered from the network although high current equipment will need to...

Страница 19: ...ce s NMEA 0183 input output connections are NOT connected to an MFD or an NMEA 0183 to SeaTalkng converter that is connected to the same network as the gateway Multiple Micro Talk gateways It is recom...

Страница 20: ...20...

Страница 21: ...n checklist on page 22 3 2 Parts supplied on page 23 3 3 Software updates on page 24 3 4 Tools required for installation on page 25 3 5 Warnings and cautions on page 26 3 6 Selecting a location on pag...

Страница 22: ...5 Drill cable and mounting holes 6 Make all connections into equipment 7 Secure all equipment in place 8 Power on and test the system Schematic diagram A schematic diagram is an essential part of plan...

Страница 23: ...t SeaTalkng White cable 5 M4 x 40mm Threaded studs x 3 used for surface mounting 6 Finger nuts x 3 used for surface mounting Unpack your product carefully to prevent damage or loss of parts check the...

Страница 24: ...sues with your product always follow the relevant update instructions carefully and in the sequence provided If in doubt as to the correct procedure for updating your product software refer to your de...

Страница 25: ...2 4 mm 11 64 drill bit for fixing studs 3 22 mm for cable hole when surface mounting 4 Pozi drive screwdriver only required for Pole mount installations 5 Size 4 2 5 mm Hex Key only required for Pole...

Страница 26: ...3 5 Warnings and cautions Important Before proceeding ensure that you have read and understood the warnings and cautions provided in the Chapter 1 Important information section of this document 26...

Страница 27: ...nning the installation location also consider the following The unit should have a clear line of sight to the Micronet products it will connect to The range for unobstructed line of sight is up to 150...

Страница 28: ...ion is required to ensure that EMC performance is not compromised Note In areas of extreme EMC interference some slight interference may be noticed on the product Where this occurs the product and the...

Страница 29: ...3 7 Product dimensions Planning the installation 29...

Страница 30: ...30...

Страница 31: ...ables and connections Chapter contents 4 1 General cabling guidance on page 32 4 2 Connections overview on page 33 4 3 SeaTalkng power supply on page 35 4 4 Network examples on page 40 Cables and conn...

Страница 32: ...and exposure to heat Use trunking or conduit where possible Do NOT run cables through bilges or doorways or close to moving or hot objects Secure cables in place using tie wraps or lacing twine Coil a...

Страница 33: ...nections Connection Qty Connects to Suitable cables 1 1 SeaTalkng backbone 2 NMEA 2000 backbone 1 SeaTalkng spur cables 2 SeaTalkng to DeviceNet adaptor cable A06045 Can connect up to 32 Compatible Mi...

Страница 34: ...clicks until it is in the locked position SeaTalkng product loading The number of products that can be connected to a SeaTalkng backbone depends on the power consumption of each product and the physic...

Страница 35: ...rops when the engines are started 2 The ACU 100 and SPX 5 cannot be used to power the SeaTalkng backbone SeaTalkng power connection point Small systems If the backbone length is 60 m 197 ft or less th...

Страница 36: ...with a different product See below for more information on implementation for some common power distribution scenarios Important When planning and wiring take into consideration other products in you...

Страница 37: ...distribution panel Alternatively the SeaTalkng power cable may be connected to a suitable breaker or switch on the vessel s distribution panel or factory fitted power distribution point The distributi...

Страница 38: ...standards BMEA Code of Practice for Electrical and Electronic Installations in Boats NMEA 0400 Installation Standard ABYC E 11 AC DC Electrical Systems on Boats ABYC A 31 Battery chargers and Inverte...

Страница 39: ...plying power to this product ensure it has been correctly grounded in accordance with the instructions provided Warning Positive ground systems Do not connect this unit to a system which has positive...

Страница 40: ...elow are provided as examples only Example system with wireless hull transmitter 1 Mast rotation sensor 2 Micronet Wind transducer 3 Micro Talk gateway 4 Wireless instrument 5 Heading source e g Evolu...

Страница 41: ...8 SeaTalkng MFD 9 SeaTalkng 5 way block 10 DST transducer 11 Wireless hull transmitter Example system with SeaTalkng DST transducer 1 Mast rotation sensor 2 Micronet Wind transducer 3 Micro Talk gatew...

Страница 42: ...4 Wireless instrument 5 Heading source e g Evolution EV sensor 6 SeaTalkng instrument 7 SeaTalkng Pilot Controller 8 SeaTalkng MFD 9 SeaTalkng 5 way block 10 DST transducer 42...

Страница 43: ...5 2 Pole or rail mounting on page 45 5 3 Surface mounting using the Deck mounting kit on page 46 5 4 Bracket mounting using the Deck mounting kit on page 48 5 5 Surface mounting using the Riser on pag...

Страница 44: ...l 3 x fixing holes and 1 x cable hole using drill bit sizes as indicated on the template 3 Place the waterproof gasket into position on the underside of the unit 4 Connect the cable to an available Se...

Страница 45: ...nd pole or b the cable exit hole 3 Connect the cable to an available SeaTalk ng spur connection then connect the other end of the cable to the connector on the underside of the unit and secure using t...

Страница 46: ...location requirements see 3 6 Selecting a location for details 1 Using the Mounting tray template 87170 drill 4 holes in the mounting surface plus a 22 mm 7 8 in hole for the SeaTalkng cable 2 Place t...

Страница 47: ...nd secure by rotating the locking collar clockwise 2 clicks 6 Insert the unit into the mounting tray ensuring the tabs in the Mounting tray are slotted into the grooves around the edge of the unit 7 P...

Страница 48: ...duct Ensure that the chosen location meets the product s location requirements see 3 6 Selecting a location for details 1 Use the Mounting bracket template 87170 to drill 3 pilot holes in the vertical...

Страница 49: ...in the cable connector on the underside of the unit and secure by rotating the locking collar clockwise 2 clicks 6 Insert the unit into the mounting tray ensuring the tabs in the Mounting tray are sl...

Страница 50: ...The Wall bracket is not required when using the Riser Ensure that the chosen location meets the product s location requirements see 3 6 Selecting a location for details 1 Use the supplied Deck mount r...

Страница 51: ...Mounting tray 6 Pull the SeaTalkng cable through the Riser and Mounting tray Plug in the cable connector on the underside of the unit and secure by rotating the locking collar clockwise 2 clicks 7 Ins...

Страница 52: ...e release hole located on the flat edge of the mounting adaptor and twist the screw driver 90 so that there is a small gap between the Mounting trim and Mounting tray Important To help prevent scratch...

Страница 53: ...stem operation and setup Chapter contents 6 1 Transducer calibration on page 54 6 2 Autonetworking on page 55 6 3 Powering the unit on and off on page 59 6 4 Data damping on page 60 System operation a...

Страница 54: ...is is particularly important with the Mast rotation device which must be linearized after and independently of your primary heading source This means 2 linearizations are required the first for the he...

Страница 55: ...remote display Performing Autonetworking Follow the steps below to add new Micronet products to an existing system or create a new system from multiple boxes Note Autonetworking should be performed b...

Страница 56: ...wer on the chosen display by pressing and holding the Down Power button for 2 seconds 5 Ensure the chosen display is not showing a Racer Timer or Wind Shift page 6 Press the Set Up button for 2 second...

Страница 57: ...k follow the steps below i Press any button on a display that has JOIN flashing onscreen The Display will show JOIN YES ii Confirm by pressing any button on the same display The display will show DONE...

Страница 58: ...ove them from the vessel 14 Ensure all units are working correctly before mounting them Product identification on Micronet The Micro Talk gateway is identified differently during the Autonetworking pr...

Страница 59: ...Talk unit will automatically power on when power is applied to the SeaTalkng network that the unit is connected to Powering off The Micro Talk unit is powered off when the SeaTalkng network it is con...

Страница 60: ...gs are set to either Slow Medium or Fast rather than Auto To determine whether you should make the damping changes on SeaTalkng or MicroNet the user should consider the other products in their network...

Страница 61: ...Chapter 7 Troubleshooting Chapter contents 7 1 Troubleshooting on page 62 7 2 LED Diagnostics on page 63 Troubleshooting 61...

Страница 62: ...oducts are subjected to comprehensive testing and quality assurance programs If you do experience problems with your product this section will help you to diagnose and correct problems in order to res...

Страница 63: ...ne Red Micronet searching for network None Green Normal operation None Red SeaTalkng connection lost Micronet will revert to searching mode after 30 seconds 1 Power cycle unit 2 Check network connecti...

Страница 64: ...64...

Страница 65: ...Chapter 8 Maintenance Chapter contents 8 1 Service and maintenance on page 66 8 2 Routine equipment checks on page 67 8 3 Product cleaning on page 68 Maintenance 65...

Страница 66: ...8 1 Service and maintenance This product contains no user serviceable components Please refer all maintenance and repair to authorized Raymarine dealers Unauthorized repair may affect your warranty 66...

Страница 67: ...d that you perform the following routine checks on a regular basis to ensure the correct and reliable operation of your equipment Examine all cables for signs of damage or wear and tear Check that all...

Страница 68: ...ghtly rinse or flush with clean cool fresh water If your product has a display screen do NOT wipe the screen with a dry cloth as this could scratch the screen coating Do NOT use abrasive acidic ammoni...

Страница 69: ...Chapter 9 Technical support Chapter contents 9 1 Raymarine product support and servicing on page 70 9 2 Learning resources on page 72 Technical support 69...

Страница 70: ...ir flir com Web support Please visit the Support area of the Raymarine website for Manuals and Documents http www raymarine com manuals FAQ Knowledgebase http www raymarine com knowledgebase Technical...

Страница 71: ...Raymarine subsidiary Russia 7 495 788 0508 info mikstmarine ru Authorized Raymarine distributor Viewing product information With your MFD Homescreen displayed 1 Select Set up 2 Select Maintenance 3 Se...

Страница 72: ...nge of in depth training courses to help you make the most of your products Visit the Training section of the Raymarine website for more information http www raymarine co uk view id 2372 FAQs and Know...

Страница 73: ...Chapter 10 Technical specification Chapter contents 10 1 Technical specification on page 74 Technical specification 73...

Страница 74: ...ting in the UK Europe or Africa 915 9 MHz for products operating in the USA Canada South America and Australia Environmental Installation environment Operating temperature 20 C to 55 C 4 F to 131 F St...

Страница 75: ...Chapter 11 Spares and accessories Chapter contents 11 1 Accessories on page 76 11 2 SeaTalk ng cabling components on page 77 11 3 SeaTalk ng cables and accessories on page 78 Spares and accessories 75...

Страница 76: ...1 Accessories The following accessories are available Accessories Item Part number Pole rail mounting adaptor kit A80370 6 m SeaTalkng white spur cable A06072 Deck mounting Clamshell Riser kit A80437...

Страница 77: ...onnected Terminator Required at either end of the backbone Inline terminator Used to connect a spur cable directly to the end of a backbone useful for longer cable runs Spur cable Used to connect devi...

Страница 78: ...2 SeaTalk ng 0 4 m 1 3 ft elbow spur A06033 SeaTalk ng 0 4 m 1 3 ft backbone A06034 SeaTalk ng 1 m 3 3 ft backbone A06035 SeaTalk ng 3 m 9 8 ft backbone A06036 SeaTalk ng 5 m 16 4 ft backbone A06068 S...

Страница 79: ...n to SeaTalk ng adaptor cable 0 4 m 1 3 ft A06045 DeviceNet adaptor cable Female Allows the connection of NMEA 2000 devices to a SeaTalk ng system A06046 DeviceNet adaptor cable Male Allows the connec...

Страница 80: ...80...

Страница 81: ...nction 126464 Transmission PGN list 126464 Received PGN list 126992 System time 126993 Heartbeat 126996 Product information 126998 Configuration information 127237 Heading track control 127250 Vessel...

Страница 82: ...82...

Страница 83: ......

Страница 84: ......

Страница 85: ...nce 27 28 See also Compass safe distance L LED status 63 LEN See Load equivalency number See Load Equivalency Number Load equivalency number 35 Location requirements 27 Locking collar 34 M Maintenance...

Страница 86: ...tection Surface mounting 44 46 50 System examples See Network examples T Technical support 70 Thermal breaker rating SeaTalkng 36 Tools 25 Troubleshooting 62 Typical systems See Network examples U Upg...

Страница 87: ......

Страница 88: ...www raymarine com Raymarine UK Limited Marine House Cartwright Drive Fareham PO15 5RJ United Kingdom Tel 44 0 1329 246 700...

Отзывы: