8.1 Alarms
You can set up alarms to alert you to certain conditions.
Alarms are raised by system functions, and also external equipment
connected to your display.
When an alarm event occurs an audible and visual alarm is activated
which indicates the alarm state.
Alarm thresholds can be configured from the relevant alarm page /
menu.
Instrument alarms
i40 Bidata
i40 Depth
i40 Speed
i40 Wind
Shallow alarm
Shallow alarm
High wind speed
alarm
Deep alarm
Deep alarm
Shallow anchor
alarm
Shallow anchor
alarm
Deep anchor
alarm
Deep anchor
alarm
Alarm indications
Shallow alarm
D12514-1
The Shallow alarm is available on both the i40 Bidata and i40 Depth
instruments. The Shallow alarm sounds when the depth is equal to
or less than the Shallow alarm threshold. The alarm sounds until
silenced manually.
Deep alarm
D12515-1
The Deep alarm is available on both the i40 Bidata and i40 Depth
instruments. The Deep alarm sounds when the depth is equal to the
Deep alarm threshold. The alarm sounds until silenced manually.
Anchor alarms
D12516-1
The anchor alarms are available on both the i40 Bidata and i40
Depth instruments. The anchor alarms sound when either:
• Depth is equal to or less than the Shallow anchor alarm threshold,
or
• Depth is equal to or more than the Deep anchor alarm threshold.
The alarm sounds until silenced manually.
High wind speed alarm
D12517-1
The High wind speed alarm is available on the i40 Wind instrument.
The High wind speed alarm sounds when the wind speed exceeds
the High wind speed alarm threshold. The alarm sounds until
silenced manually.
True wind
— If vessel speed information is available at the
instrument (from a SeaTalk bus) the alarm is triggered if True wind
speed exceeds the threshold.
Apparent wind
— If vessel speed information is not present, the
alarm is triggered if the Apparent wind speed exceeds the threshold.
Silencing alarms
1. Press any button to silence an active alarm.
Enabling / Disabling alarms
With the relevant alarm page displayed:
1. Press and hold the
Up
button for 3 seconds to switch the alarm
on or off.
Setting alarm thresholds
D12518-1
+
-
+
With the relevant alarm page displayed:
1. Press the
Up
and
Down
button simultaneously to enter edit
mode.
2. Use the
Up
button to increase the alarm threshold.
3. Use the
Down
button to decrease the alarm threshold.
4. Press the
Up
and
Down
button simultaneously to save the new
alarm threshold and exit edit mode.
Note:
The illustration above is an example depicting setting the
Deep alarm threshold on an i40 Depth instrument.
44
i40
Содержание i40
Страница 2: ......
Страница 4: ......
Страница 6: ...6 i40...
Страница 16: ...16 i40...
Страница 26: ...26 i40...
Страница 34: ...34 i40...
Страница 42: ...42 i40...
Страница 43: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 44 Using alarms 43...
Страница 56: ...56 i40...
Страница 57: ...Chapter 11 Technical support Chapter contents 11 1 Raymarine customer support on page 58 Technical support 57...
Страница 62: ...62 i40...
Страница 67: ......
Страница 68: ...www raymarine com...