Appendix E: Connecting A Raytheon ST80 Active Compass for MARPA
E-3
A
ppend
ix E:
Conne
ct
in
g A
R
ay
the
on
S
T8
0
Autopilot 4000/5000
If you have a Raytheon Autopilot 4000 or 5000 (with compass) and a
Raytheon active compass, we recommend that you configure your system as
follows:
•
Ensure the active compass is re-wired to provide heading data on NMEA.
•
Provide 12V power to the active compass.
•
Connect the active compass to the NMEA input of your display.
•
Enable
Bridge NMEA Heading
in the display System Set Up menu.
•
Calibrate the autopilot’s compass (as described in the autopilot Owner’s
Handbook) with the10.4" LCD/10" CRT display switched OFF.
•
Manually calibrate the NMEA compass with the 10.4" LCD/10" CRT dis-
play switched ON as described in the section
Calibrating the ST80 Active
Compass.
Note that both compasses are linearised and aligned. When the radar is ON,
the SeaTalk heading from the HSB Series display takes precedence in the
autopilot; when the HSB Series display is switched off, the autopilot uses the
locally connected compass. If the two compasses are mismatched, the
autopilot heading will change when the radar is switched on/off
SeaTalk
NMEA
Autopilot Display
D4124-2
10.4" LCD / 10" CRT Display
DISPLAY
RANGE
MARKS
VRM/EBL
ALARMS
GAIN
SEA
MULTI
MOB
ENTER
CLEAR
MENU
POWER
Compass
Compass
Содержание hsb2 Series
Страница 2: ...HSB Series Color LCD Display Owner s Handbook Document number 81165_2 Date 7th July 2000...
Страница 3: ......
Страница 42: ...Chapter 2 Getting Started Adjusting the Display 2 11 Selecting the Mode of Operation...
Страница 65: ...2 34 HSB Series Color LCD Display Displaying the Radar and Synchronizing Radar Chart...
Страница 161: ...7 20 HSB Series Color LCD Display Position Offset...
Страница 201: ...A 4 HSB Series LCD Color Display Appendix A Specification...
Страница 207: ...B 6 HSB Series Color LCD Display Appendix B Using the Auxiliary Junction Box...
Страница 231: ...viii HSB Series Color LCD Display...