Implementation — connection to distribution panel
• Alternatively, the unit’s power connection may be connected to a suitable breaker or switch on the
vessel's power distribution panel, or factory-fitted power distribution point.
• The distribution point should be fed from the vessel’s primary power source by 8AWG (8.36mm
2
)
cable.
• The unit also requires a separate RF Ground (drain) connection, refer to the following section:
Grounding — Dedicated drain wire required
.
• Ideally, all equipment should be wired to individual suitably-rated thermal breakers or fuses, with
appropriate circuit protection. Where this is not possible and more than 1 item of equipment shares
a breaker, use individual in-line fuses for each power circuit to provide the necessary protection.
• In all cases, observe the recommended breaker ratings provided in the following table.
Thermal breaker ratings — connection via distribution panel
ACU
Thermal breaker rating
ACU-100
10 A
ACU-150
15 A
ACU-200
20 A
ACU-300
15 A
ACU-400
40 A
Important:
Be aware that the suitable fuse rating for the thermal breaker or fuse is dependent on the number
of devices you are connecting.
Grounding
Ensure that you observe the dedicated grounding advice provided.
More information
It is recommended that best practice is observed in all vessel electrical installations, as detailed
in the following standards:
• BMEA Code of Practice for Electrical and Electronic Installations in Boats
• NMEA 0400 Installation Standard
• ABYC E-11 AC & DC Electrical Systems on Boats
• ABYC A-31 Battery chargers and Inverters
• ABYC TE-4 Lightning Protection
ACU-200, ACU-300, ACU-400 connections
91
Содержание Evolution EV-1
Страница 2: ......
Страница 4: ......
Страница 13: ...Chapter 2 Document information Chapter contents 2 1 Handbook information on page 14 Document information 13...
Страница 34: ...Item Description Quantity 4 Mounting screws 2 5 Document pack 1 34...
Страница 36: ...5 1 Dimensions EV 1 and EV 2 36...
Страница 37: ...5 2 Dimensions ACU 100 ACU 150 Product dimensions 37...
Страница 38: ...5 3 Dimensions ACU 200 ACU 300 ACU 400 38...
Страница 39: ...Chapter 6 Installation sequence Chapter contents 6 1 Installation checklist on page 40 Installation sequence 39...
Страница 54: ...54...
Страница 66: ...66...
Страница 80: ...Item Wire color ACU 100 ACU 150 1 Red 2 Blue 3 Green 4 Gray screen 80...
Страница 82: ...82...
Страница 104: ...104...
Страница 114: ...114...
Страница 115: ...Chapter 13 Operation Chapter contents 13 1 Evolution autopilot operation instructions on page 116 Operation 115...
Страница 128: ...128...
Страница 134: ...134...
Страница 138: ......
Страница 141: ......