6.6 System data troubleshooting
Aspects of the installation can cause problems with the data shared between connected equipment. Such problems, their possible
causes and solutions are described here.
Problem
Possible causes
Possible solutions
Check the data bus (e.g. SeaTalk
ng
) wiring and connection to the display.
Check the overall integrity of the data bus (e.g. SeaTalk
ng
) wiring.
Data is not being received at the display.
If available refer to the reference guide for the data bus. (e.g. SeaTalk
ng
reference manual)
Check the source of the missing data (e.g. ST70 instrument or engine
interface).
Check the power to the SeaTalk bus.
Data source (e.g ST70 instrument or
engine interface) is not operating.
Refer to the manufacturer’s handbook for the equipment in question.
Instrument, engine or other system data is
unavailable at all displays.
Software mismatch between equipment
may prevent communication.
Contact Raymarine technical support.
Check that all required equipment is connected to the SeaTalk
hs
switch.
Check the status of the SeaTalk
hs
Switch.
SeaTalk
hs
network problem
Check that SeaTalk
hs
cables are free from damage.
Instrument or other system data is missing
from some but not all displays.
Software mismatch between equipment
may prevent communication.
Contact Raymarine technical support
Troubleshooting
73
Содержание E90W
Страница 2: ......
Страница 4: ......
Страница 12: ...12 E Series Widescreen installation...
Страница 80: ...80 E Series Widescreen installation...
Страница 84: ...84 E Series Widescreen installation...
Страница 92: ...92 E Series Widescreen installation...
Страница 103: ......
Страница 104: ...www raymarine com...