background image

4.3 Power connection

Power is supplied to the product over the SeaTalk

ng

network.

A SeaTalk

ng

system requires one 12 V dc supply,

connected to the SeaTalk

ng

backbone. This can be

provided:

• By a battery via the distribution panel, or

• From a Raymarine course computer, via a SeaTalk

or a SeaTalk

ng

system.

In-line fuse and thermal breaker ratings

The following in-line fuse and thermal breaker ratings
apply to your product:

In-line fuse rating

Thermal breaker rating

5 A

3 A (if only connecting one
device)

Note:

• The suitable fuse rating for the thermal breaker

is dependent on the number of devices you are
connecting. If in doubt consult an authorized
Raymarine dealer.

• Your product’s power cable may have a fitted

in-line fuse, if not then you must add an in-line
fuse / breaker to the positive wire of your
products power connection.

Power distribution

Recommendations and best practice.

• The product is supplied with a power cable. Only

use the power cable supplied with the product. Do
NOT use a power cable designed for, or supplied
with, a different product.

• Refer to the

Power connection

section for more

information on how to identify the wires in your
product’s power cable, and where to connect them.

• See below for more information on implementation

for some common power distribution scenarios.

Important:

When planning and wiring, take into

consideration other products in your system, some
of which (e.g. sonar modules) may place large
power demand peaks on the vessel’s electrical
system.

Note:

The information provided below is for

guidance only, to help protect your product. It
covers common vessel power arrangements, but
does NOT cover every scenario. If you are unsure
how to provide the correct level of protection,
please consult an authorized Raymarine dealer or
a suitably qualified professional marine electrician.

Implementation — direct connection to battery

• The power cable supplied with your product may

be connected directly to the vessel's battery, via a
suitably rated fuse or breaker.

• The power cable supplied with your product may

NOT include a separate drain wire. If this is the

case, only the power cable’s red and black wires
need to be connected.

• If the supplied power cable is NOT fitted with an

inline fuse, you MUST fit a suitably rated fuse or
breaker between the red wire and the battery’s
positive terminal.

• Refer to the inline fuse ratings provided in the

product’s documentation.

• If you need to extend the length of the power cable

supplied with your product, ensure you observe
the dedicated

Power cable extensions

advice

provided in the product’s documentation.

D13344-1

A

B

A

Battery connection scenario A: suitable for a vessel with
a common RF ground point. In this scenario, if your
product’s power cable is supplied with a separate drain
wire then it should be connected to the vessel’s common
ground point.

B

Battery connection scenario B: suitable for a vessel
without a common grounding point. In this case, if your
product’s power cable is supplied with a separate drain
wire then it should be connected directly to the battery’s
negative terminal.

Implementation — connection to distribution
panel

D13348-1

• Alternatively, the supplied power cable may be

connected to a suitable breaker or switch on the
vessel's distribution panel or factory-fitted power
distribution point.

• The distribution point should be fed from the

vessel’s primary power source by 8 AWG
(8.36 mm

2

) cable.

• Ideally, all equipment should be wired to individual

suitably-rated thermal breakers or fuses, with
appropriate circuit protection. Where this is not
possible and more than 1 item of equipment
shares a breaker, use individual in-line fuses
for each power circuit to provide the necessary
protection.

Cables and connections

19

Содержание E70196

Страница 1: ...NMEA 0183 to SeaT alk ng con ve r t e r Installation instructions English Date 06 2015 Document number 87256 1 EN 2015 Raymarine UK Limited...

Страница 2: ......

Страница 3: ...patents design patents patents pending or design patents pending Fair Use Statement You may print no more than three copies of this manual for your own use You may not make any further copies or dist...

Страница 4: ......

Страница 5: ...cautions 14 3 6 General location requirements 14 3 7 Product dimensions 15 Chapter 4 Cables and connections 17 4 1 General cabling guidance 18 4 2 Connections overview 18 4 3 Power connection 19 4 4 V...

Страница 6: ...6 NMEA 0183 SeaTalkng converter...

Страница 7: ...ntenance and repair to authorized Raymarine dealers Unauthorized repair may affect your warranty Water ingress Water ingress disclaimer Although the waterproof rating capacity of this product meets th...

Страница 8: ...to the cable near the Raymarine unit Declaration of conformity Raymarine UK Ltd declares that this product is compliant with the essential requirements of EMC directive 2004 108 EC The original Decla...

Страница 9: ...Chapter 2 Document and product information Chapter contents 2 1 Document information on page 10 2 2 Product overview on page 10 Document and product information 9...

Страница 10: ...ta to the VHF radio Note The converter supports only uni directional one way communication from the SeaTalkng bus to the NMEA device For example it only supports the output of GPS position data from a...

Страница 11: ...ation checklist on page 12 3 2 Parts supplied on page 12 3 3 Software updates on page 13 3 4 Tools required on page 13 3 5 Warnings and cautions on page 14 3 6 General location requirements on page 14...

Страница 12: ...t is also useful for any future additions or maintenance of the system The diagram should include Location of all components Connectors cable types routes and lengths 3 2 Parts supplied D12832 2 1 4 5...

Страница 13: ...t Caution Downloading software updates The software update process is carried out at your own risk Before initiating the update process ensure you have backed up any important files Ensure that the un...

Страница 14: ...ansmitters receivers Magnetic compass refer to the Compass safe distance section in this document for advice on maintaining a suitable distance between this product and any compasses on your vessel Po...

Страница 15: ...3 7 Product dimensions 30 2 mm 1 19 in D13367 1 109 45 mm 4 3 in 21 45 mm 0 84 in 90 mm 3 54 in Planning the installation 15...

Страница 16: ...16 NMEA 0183 SeaTalkng converter...

Страница 17: ...s and connections Chapter contents 4 1 General cabling guidance on page 18 4 2 Connections overview on page 18 4 3 Power connection on page 19 4 4 VHF radio connection NMEA 0183 on page 21 Cables and...

Страница 18: ...quipment and cables high current carrying ac and dc power lines antennae Strain relief Ensure adequate strain relief is provided Protect connectors from strain and ensure they will not pull out under...

Страница 19: ...r a suitably qualified professional marine electrician Implementation direct connection to battery The power cable supplied with your product may be connected directly to the vessel s battery via a su...

Страница 20: ...8AWG 0 82 mm2 for any length of cable extension For all lengths of extension to the power cable ensure there is a continuous minimum voltage at the product s power connector of 10 8 V with a fully fla...

Страница 21: ...spur 3 SeaTalkng to NMEA 0183 bare wires spur cable 4 Converter NMEA 0183 negative connection yellow wire 5 NMEA 0183 device input negative connection purple wire 6 Converter NMEA 0183 positive conne...

Страница 22: ...22 NMEA 0183 SeaTalkng converter...

Страница 23: ...Chapter 5 Mounting Chapter contents 5 1 Mounting the unit on page 24 Mounting 23...

Страница 24: ...es 4 Using an appropriate size drill bit drill 2 holes at the marked locations 5 Position the converter so that the mounting holes of the unit line up with the drilled holes in the mounting surface 6...

Страница 25: ...Chapter 6 System checks and troubleshooting Chapter contents 6 1 System checks on page 26 6 2 Troubleshooting on page 27 System checks and troubleshooting 25...

Страница 26: ...t instrument data is accurate and is available at all appropriate displays and instruments LifeTag MOB functional test Check that the LifeTag system generates the appropriate warnings alarms at all ap...

Страница 27: ...and shipping subjected to comprehensive test and quality assurance programs However if you experience problems with the operation of your product this section will help you to diagnose and correct pro...

Страница 28: ...pport Check that all required equipment is connected to the network Check the status of the Raymarine network Switch Network problem Check that SeaTalkhs RayNet cables are free from damage Instrument...

Страница 29: ...Chapter 7 Maintenance Chapter contents 7 1 Routine checks on page 30 7 2 Unit cleaning instructions on page 30 Maintenance 29...

Страница 30: ...e properly engaged Note Cable checks should be carried out with the power supply switched off 7 2 Unit cleaning instructions The unit does not require regular cleaning However if you find it necessary...

Страница 31: ...Chapter 8 Technical support Chapter contents 8 1 Raymarine product support and servicing on page 32 8 2 Viewing product information on page 33 Technical support 31...

Страница 32: ...air flir com Web support Please visit the Support area of the Raymarine website for Manuals and Documents http www rayma rine co uk display id 10125 FAQ Knowledgebase http www rayma rine co uk knowled...

Страница 33: ...as product serial number and software version With the Homescreen displayed 1 Select Set up 2 Select Maintenance 3 Select Diagnostics 4 Select the Select Device option A list of connected devices is d...

Страница 34: ...34 NMEA 0183 SeaTalkng converter...

Страница 35: ...Chapter 9 Technical specification Chapter contents 9 1 Technical specification on page 36 Technical specification 35...

Страница 36: ...o Seatalkng reference manual for further information LEN 1 Environmental Installation environment Operating temperature 10 C to 50 C 14 F to 122 F Storage temperature 20 C to 65 C 4 F to 149 F Relativ...

Страница 37: ...Chapter 10 Spares and accessories Chapter contents 10 1 SeaTalkng cables and accessories on page 38 Spares and accessories 37...

Страница 38: ...able A06049 SeaTalkng Terminator A06031 SeaTalkng T piece A06028 Provides 1 x spur connection SeaTalkng 5 way connector A06064 Provides 3 x spur connections SeaTalkng backbone extender A06030 SeaTalk...

Страница 39: ...eaTalkng GGA will transmit only the available data fields for example time and date 129029 GPS statistics and Latitude and Longitude 129033 Time and date 129026 COG SOG 127258 Variation 65311 Variatio...

Страница 40: ...40 NMEA 0183 SeaTalkng converter...