4.1 General cabling guidance
Cable types and length
It is important to use cables of the appropriate type and length
• Unless otherwise stated use only standard cables of the correct
type, supplied by Raymarine.
• Ensure that any non-Raymarine cables are of the correct quality
and gauge. For example, longer power cable runs may require
larger wire gauges to minimize voltage drop along the run.
Routing cables
Cables must be routed correctly, to maximize performance and
prolong cable life.
• Do NOT bend cables excessively. Wherever possible, ensure a
minimum bend diameter of 200 mm (8 in) / minimum bend radius
of 100 mm (4 in).
100 mm (4 in)
200 mm (8 in)
• Protect all cables from physical damage and exposure to heat.
Use trunking or conduit where possible. Do NOT run cables
through bilges or doorways, or close to moving or hot objects.
• Secure cables in place using tie-wraps or lacing twine. Coil any
extra cable and tie it out of the way.
• Where a cable passes through an exposed bulkhead or deckhead,
use a suitable watertight feed-through.
• Do NOT run cables near to engines or fluorescent lights.
Always route data cables as far away as possible from:
• other equipment and cables,
• high current carrying ac and dc power lines,
• antennae.
Strain relief
Ensure adequate strain relief is provided. Protect connectors from
strain and ensure they will not pull out under extreme sea conditions.
Cable shielding
Ensure that all data cables are properly shielded that the cable
shielding is intact (e.g. hasn’t been scraped off by being squeezed
through a tight area).
4.2 Connections overview
Connections are made using the provided SeaTalk
ng
and transducer
cable connectors on the rear of the unit.
SeaTalk
ng
connections
The unit has 2 x SeaTalk
ng
connectors on the rear for connecting
to a SeaTalk
ng
network.
D12056-1
Connecting SeaTalk
ng
cables
1. Rotate the locking collar on the back of the unit to the
UNLOCKED position.
2. Ensure the spur cable end connector is correctly oriented.
3. Fully insert the cable connector.
4. Rotate locking collar clockwise (2 clicks) until it snaps into the
LOCKED position.
Transducer connections
i50 Depth connection
D12376-1
2
1
3
Item
Cable color
Signal name
1
Black
Piezoceramic –
2
Blue
Piezoc
3
Screen
0 V (shield)
20
i50
Содержание E70058
Страница 2: ......
Страница 4: ......
Страница 6: ...6 i50 ...
Страница 18: ...18 i50 ...
Страница 24: ...24 i50 ...
Страница 38: ...38 i50 ...
Страница 45: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 46 Using alarms 45 ...
Страница 64: ...13 4 Converters Part number Description E22158 SeaTalk to SeaTalkng Converter 64 i50 ...
Страница 66: ...66 i50 ...
Страница 67: ......
Страница 68: ...www raymarine com ...