9.1 CP370 Technical specification
Physical specification
Dimensions
•
Width
: 299.4 mm (11.79 in).
•
Height
: 205.6 mm (8.1 in).
•
Height (including connectors)
: 285.6 mm
(11.2 in).
•
Depth
: 84.4 mm (3.3 in).
Weight
1.435 kg (3.16 lbs)
Power specification
Nominal supply voltage
12 V / 24 V dc
Operating voltage range
10.8 V to 31.2 V dc
Power consumption
30.6 W (Maximum)
Current
3 A RMS
Fuse / breakers
5 A
Environmental specification
Operating temperature
–10°C (14°F) to +55°C (131°F)
Storage temperature
–30°C (22°F) to +70°C (158°F)
Relative humidity
95%
Waterproof rating
IPX6
Sonar specification
Frequency
50 kHz and 200 kHz
Power output
Up to 1 KW RMS
Depth
0.9 m (3 ft) to 1524 m (5,000 ft) (In optimum conditions and depending
on transducer connected)
Transducer
Transom-mount, in-hull, thru-hull
Connections
• 1 x Power connection
• 1 x network connection (RayNet connector) 10 / 100 Mb/s
• 1 x Transducer connection
Conformance specification
Conformance
• EN 60945:2002
• EMC Directive 2014/30/EU
• Australia and New Zealand: C-Tick,
Compliance Level 2