Item
Description
3
Circuit breaker
4
Waterproof fuse holder containing a suitably-rated inline fuse
must be fitted. For suitable fuse rating, refer to:
Inline fuse and
thermal breaker ratings
.
Important:
Observe the recommended fuse / breaker ratings provided in the product’s
documentation, however be aware that the suitable fuse / breaker rating is
dependent on the number of devices being connected.
Implementation — direct connection to battery
• Where connection to a power distribution panel is not possible, the power
cable supplied with your product may be connected directly to the vessel's
battery, via a suitably rated fuse or breaker.
• The power cable supplied with your product does NOT include a separate
drain wire. Therefore, only the power cable’s red and black wires need
to be connected.
• If the power cable is NOT supplied with a fitted inline fuse, you MUST fit
a suitably rated fuse or breaker between the red wire and the battery’s
positive terminal.
• Refer to the inline fuse ratings provided in the product’s documentation.
• If you need to extend the length of the power cable supplied with your
product, ensure you observe the dedicated
Power cable extensions
advice
provided in the product’s documentation.
Item
Description
1
Waterproof fuse holder containing a suitably-rated inline fuse
must be fitted. For suitable fuse rating, refer to:
Inline fuse and
thermal breaker ratings
.
2
Product power cable.
More information
It is recommended that best practice is observed in all vessel electrical
installations, as detailed in the following standards:
• BMEA Code of Practice for Electrical and Electronic Installations in Boats
• NMEA 0400 Installation Standard
• ABYC E-11 AC & DC Electrical Systems on Boats
• ABYC A-31 Battery chargers and Inverters
• ABYC TE-4 Lightning Protection
11.5 Power cable extension (12 V systems)
If you need to extend the length of the power cable supplied with your
product, ensure you observe the following advice:
• The power cable for each unit in your system should be run as a separate,
single length of 2-wire cable from the unit to the vessel's battery or
distribution panel.
• Ensure that the extension cable is of a sufficient gauge for the supply
voltage and the total load of the device and the length of the cable run.
Refer to the following table for typical
minimum
power cable wire gauges:
Cable length in meters (feet)
Wire gauge in AWG (mm
2
) for 12 V
supply
<8 (<25)
16 (1.31 mm
2
)
16 (50)
14 (2.08 mm
2
)
24 (75)
12 (3.31 mm
2
)
>32 (>100)
10 (5.26 mm
2
)
41
Содержание CAM300