Service Manual Rayjet
FAQ’s
finished correctly
on the computer
0
Engraved or cut job
size doesn’t match
with size in Corel
Draw
Ò
-Raster correction ON
Ò
Wrong size settings in the printer
driver
Ò
Wrong image position is selected in
the layout tab ( printing )
Ò
Wrong machine is selected in the
JobControl
¬
Switch off raster correction in
JobControl (settings/advanced
options/laser tab)
¬
Use the same size as in Corel
draw
¬
Switch in the layout settings to :
as in document
¬
Switch to the proper machine
0
the center of jobs
is different to the
edges
Ò
Incorrect factor K1
Ò
Loose belt
Ò
Defect X-Axis
¬
¬
¬
0
Curves looks a little
bit angular in
acrylic
Ò
You have the wrong program for this
application
¬
Use a CAD / CAM software like
TROCAM to get really smooth
curves
0
Ò
The power correction is to low
¬
Settings / Material Templates
Setup.—correction—
11.2 Machine malfunctions
11.2.1 No error code is created
Problem description:
Possible reason:
Solution:
0
no referencing
0
after start up
Ò
top, front or side door not closed
Ò
defect in the interlock system
Ò
mechanical problem on axis
Ò
bad limit switch
Ò
defect power supply
¬
close doors
¬
check interlocks
¬
make sure that the mechanical
resistance is small
¬
replace the limit switch
¬
measure voltage, if necessary
replace it
0
no response at
switching on of
the system
Ò
main fuses blown
Ò
power supply defect
Ò
FRAM defective
¬
replace fuses
¬
replace power supply
¬
refresh FRAM / exchange CPU
0
no communication to
machine
Ò
invalid COM port selection
Ò
serial cable defect
Ò
COM port is in use by an other
program
¬
change selection
¬
replace cable
¬
close this program, or change the
COM port
0
connection to
machine breaks
frequently
Ò
electromagnetic imissions
¬
make sure that machine and
computer are connected to the
same electric circuit
the original cable lengths
should not be exceeded
0
offsets between
Ò
dusty encoder
Ò
top speed too high
¬
clean encoder
¬
reduce speed
07/09/2010