@2021 Raycus Corporation
2
f)
The device has four cooling fans at the rear panel to dissipate heat. In order to
guarantee enough airflow to help giving heat off, there must be a space of at least 10
cm’s width for airflow in front and rear side of the device. As the cooling fans are
working at blow condition, if laser is mounted in a cabinet with fans, the direction
should be same as laser’s fans.
g)
Do not look into the output head of the device directly. Please do wear appropriate laser
safety eyewear during operation of the device.
h)
The longest time without pulse is only 100
s
. If there is no pulse output, please stop
marking at once to avoid the further damage of the device.
i)
Power source sudden interruption will do great harm to the laser device. Please make
sure the power supply works continuously.
1.4.
Specifications
Table 2 P60MX pulsed fiber laser specifications
NO.
Characteristic
Test condition
Min
Typ.
Max.
Unit
1
Mode of operation
Pulsed
2
Polarization
Random
3
Maximum pulse energy
350ns/40kHz/60W
1.5
mJ
4
Nominal average output power
60
63
65
W
5
Pulse duration
Subject to Table 3
10
/
350
ns
6
Output power adjustment
range
0
/
100
%
7
Long-term average power
instability
5
%
8
Pulse repetition rate
Subject to Table 3
1
/
2000
kHz
9
Central emission wavelength
FWHM
1059
1064
1069
nm
10
Emission bandwidth
FWHM
3
8
10
nm
11
Beam quality M
2
350ns/40kHz/60W
1.3
/
1.6
12
Output beam diameter
350ns/40kHz/60W
6
7
8
mm
13
Laser switching ON time
0-100% power
0
/
100
μ
s
14
Laser switching OFF time
100-10% power
0
3
30
μ
s
15
Output fiber cable length
/
3
/
m
16
Supply voltage
23
24
25
VDC
17
Guide Laser Power
0.2
0.5
1
mW
18
Anti Strong Back Reflection
Yes
19
Cooling
Forced Air Cooled
20
Operating Temperature
0
/
40
℃