Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-P500
20
5
Application Steps of Laser Device
5.1
Pre-inspection
a)
Check whether the size and connection of water pipe are correct, mainly
including water temperature, water flow rate, maximum input pressure,
refrigeration capacity, whether the water cooler meets the system
requirements (see Section 3.3 for details), whether the water cooler valve is
opened, etc., to ensure that the water cooler is in normal working state
before the laser is opened.
b)
Check whether the appearance of the laser device is normal and whether
the output optical cable is bent or falling off.
c)
Check whether there is dust or other dirt in the protective lens of the output
optical cable. Use compressed air to confirm whether it can be blown off. If
not, wipe it gently with the lens paper dipped in alcohol, and then check it
with a special flashlight.
d)
Check whether the power supply and control signal of the laser are
connected correctly.
e)
Check whether the emergency stop switch is loose.
5.2 Operational Steps
a)
Start-up operation steps
Power on the laser, turn on the air switch, turn on the key switch (the key
switch is turned clockwise to ON position, the power indicator lights up,
indicating that the main control board has been powered on), wait 10
seconds and then press the laser switch (the light of the indicator indicates
that the power module of the laser has been powered on normally).
b)
Operational procedures for checking laser cleaning after laser is turned on
When the device is started normally, the laser power will be increased from
10% to 100% when the laser is first tested. Watch whether the laser is
getting stronger and stronger as a cleaning material.