Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-P500
14
protective cover and a lock catch. Please use the protective cover and
lock catch when not use the laser device.
2.
POWER:
Air switch. Controlling the on-off of AC.
3.
CTRL-INTERFACE:
Control interface. This interface provides all
control signals, including RS232 communication, laser switch control,
laser remote control mode selection, analog control, modulation signal,
Interlock interface. Please reference table 4 for specific definition of
control line. The socket is provided with a protective cover and a lock
catch. Please use the protective cover and lock catch when not use the
laser device.
4.
RS-232:
RS-232 interface. Provides remote control and fault
information storage for lasers. See 4.4.3 for details.
5.
SERVICE:
Provide some external functions for customers. See 4.4.1
Interface Specification for details.
6.
WATER
:
The pagoda typepipe connector. The intake and outlet are
used for inflow and reflux cooling water.
4.3
Power Connection
CAUTION:
a)
Before connect the product to AC power, you must check up
that the AC supply you will apply is in accordance with the
specifications provided in Table 1.
b)
Failure to correctly connect the cable could damage the device.
Please check whether the power cable and the control cable is
correctly connected before usage.
A power cord is provided in the package, as in Figure 6