background image

 

 

Wuhan Raycus Fiber Laser Technologies CO., Ltd.

 

P30MX Pulsed Fiber Laser User’s Guide V1 

 

@2021 Raycus Corporation 

 

 

For example, if using Beijing JCZ Technology Co. marking card to adjust laser pulse 

duration, the setting processes are described as follows:

 

a)

 

Make  sure  the  power  supply,  DB25  cable,  control  card  and  computer  are  correctly 

connected, and then turn on the 24V power supply. 

b)

 

Open  Ezcad2.7.6  (or  other  versions),  then  click  ‘F3’,  the  configuration  parameter 

should show up, select ‘Fiber’ in the category of the ‘Laser Control’ panel, follow that 

select ‘IPG_YLPM’, and then close this window. 

c)

 

Pulse duration can be modified by the ‘Duration’ on the right side of the window. If the 

setting duration is smaller than the limiting minimum value, the duration of output laser 

will  be  2ns  (minimum).  If  the  setting  duration  is  larger  than  the  limiting  maximum 

value,  the  duration  of  output  laser  will  be  continuous  work  (maximum). If  the  setting 

duration within the range, the duration of output laser will tend to the smaller side. 

 

4.

 

Operation Regulations 

4.1.

 

Pre-inspection 

a)

 

Make  surethe  device  appearance  is  in  good  condition  and  the  output  fiber  is  neither 

excessively bended nor broken. 

b)

 

Make sure signal line of laser and marking system are properly connected. 

4.2.

 

Operation procedures 

a)

 

Starting procedures 

1)

 

Please make sure the control  system is  on before  you turn on the fiber laser. Only 

after at least 1 

2)

 

minute since the power turned on, the subsequent operations can be proceeded. 

b)

 

Frequency set introductions 

The frequency setting range is from 1 kHz to 2000 kHz. 

c)

 

Laser marking checking 

For  the  device  initial  testing,  first  turn  the  power  down  to  zero  without  turning  on  the 

marking  system  after  the  device  is  successfully  started.  Then  draw  a  quadrate,  marking 

continuously while slowly increasing the power from 1% to 100% at the same time. Meanwhile, 

use a ceramic material to observe the laser and the laser should become stronger, otherwise shut 

down the device and check.  

If operating normally, the marking system can be used in common order afterwards.

 

Содержание RFL-P30MX

Страница 1: ...A0 C RFL P30MX 30MX RFL P30MX JS02 20210303 20210305 20210305 20210305 20210308...

Страница 2: ...User Instruction RFL P30MX Wuhan Raycus Fiber Laser Technologies CO Ltd 2021...

Страница 3: ...se make sure that the correct voltage of 24V DC is connected and the anode and cathode are right Incorrect polarityor voltage will harm severely the device b The device emits invisible light with a wa...

Страница 4: ...list 1 1 3 Environmental requirements and cautions 1 1 4 Specifications 1 2 Mounting 1 2 1 Mounting dimensions 1 2 2 Method of installation 2 3 Control Interface 3 4 Operation Regulations 7 4 1 Pre i...

Страница 5: ...ser is shown in Figure 2 The laser is pumPing by the way of fiber coupling output semiconductor laser so the efficiency of pump light conversion is very high The laser uses air cooling system and thef...

Страница 6: ...ls to follow this instruction the protective function will be weakened Therefore it should be used under normal conditions e Do not install the collimating device into the output head when the laser d...

Страница 7: ...pulses of a pulse duration from 2ns to 500ns see Table 2 are used the nominal output rated power is Pmax 30W if the pulse repetition rate PRR is greater than the corresponding cut off pulse repetition...

Страница 8: ...verage power instability 5 8 Pulse repetition rate 1 2000 kHz 9 Central emission wavelength FWHM 1060 1064 1085 nm 10 Emission bandwidth FWHM 3 8 15 nm 11 Beam quality M2 1 5 12 Output beam diameter 8...

Страница 9: ...gure 4 Relation between pulse repetition rate PRR and maximum average power P Figure 5 Relation between pulse repetition rate PRR and maximum average power P forvarious pulse duration 0 500 1000 1500...

Страница 10: ...rious pulse duration Figure 7 Relation between pulse repetition rate PRR and maximum average power Epulseforvarious pulse duration 0 100 200 300 400 500 0 5 10 15 20 25 30 average laser power P W puls...

Страница 11: ...r different pulse duration NO ns PRRmin kHz PRR0 kHz PRRmax kHz Pmax W EPules max mJ 1 2 1 2000 2000 30 0 015 2 4 1 500 2000 30 0 06 3 8 1 375 1000 30 0 08 4 14 1 250 1000 30 0 12 5 20 1 170 1000 30 0...

Страница 12: ...aser User s Guide V1 2021 Raycus Corporation 1 2 Mounting 2 1 Mounting dimensions Figure 9 Dimension drawing of laser module Unit mm Figure 10 Dimension drawing of output isolator Unit mm Figure 11 Wi...

Страница 13: ...e power line to 24VDC power and ensure enough DC output power Keep it clear to the polarity of the electric current Anode brown Cathode blue PE yellow and green c Make sure that the interface of the e...

Страница 14: ...0XFF 10 14 Ground Digital GND 11 12 16 21 Laser alarms status see alarm codes in Table 5 17 VCC 5VDC power supply input for independent operation of the guide laser and PCB 18 EE Emission Enable EE s...

Страница 15: ...is the start signal of the MO Pin19 is the input for the optical output signal The electrical level for both Pin18 and Pin19 are 5V Before turning on Pin 19 MO signal must be switched ON in other word...

Страница 16: ...n meet the needs of most users Special needs shall be put forward in the customized contract g Definition of alarm signal Table 6 Definition of alarm signal Pin12 Pin11 Pin16 Pin21 Alarm content Low L...

Страница 17: ...o the laser machine is 0xA5 instruction code 3 0xA5 A5h is the comment byte to active the laser pulse duration control port 0xA5 and the following data will be directly sent as the serial input form t...

Страница 18: ...g duration within the range the duration of output laser will tend to the smaller side 4 Operation Regulations 4 1 Pre inspection a Make surethe device appearance is in good condition and the output f...

Страница 19: ...r s Guide V1 2021 Raycus Corporation 8 4 3 Cautions a Marking frequency must be in the range of 1 kHz to 2000 kHz b It should not modify the frequency while marking c Stop marking first before shuttin...

Страница 20: ...maintenance damages due to excessive use or notfollowing the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the...

Отзывы: