background image

                        

 

               

User’s guide      Ytterbium Pulsed Fiber Laser      RFL-P10Q

/

P20Q/ P30Q/ P20QE/P50QB   Ver.: 2.0

   

                                                                                                                    

 

               

                                                                                                                         

 

 

3

 / 

9

 

 

2.

 

Mounting 

2.1 Mounting dimensions 

1) Fiber Laser module dimensions (As shown in Fig. 1). 

 

Figure 1. Dimension drawing of laser module (Unit: mm). 

2) Isolated output head dimensions (As shown in Fig. 2).

 

 

Figure 2. Dimension drawing of output isolator (Unit: mm). 

2.2   Method of installation 

1)

 

Fix the module stable to the bracket and keep the laser in good ventilation.   

2)

 

Connect the power line to 24VDC power and ensure enough DC output power. Keep it clear 

Содержание RFL-P20QE

Страница 1: ...RFL P10Q P50QB 9 RFL P10Q P20Q P30Q P20QE P50QB...

Страница 2: ...FL P10Q P20Q P30Q P20QE P50QB Ver 2 0 Ytterbium Pulsed Fiber Laser User s Guide RFL P10Q RFL P20QE RFL P20Q RFL P30Q RFL P50QB Wuhan Raycus Fiber Laser Technologies Co Ltd 2018 Proprietary information...

Страница 3: ...vice Before supplying the power to the device please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right Failure to connect power source correctly...

Страница 4: ...ironmental requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 3 3 Control Interface 5 4 Operation Regulations 8 4 1 Pre inspection 8 4 2...

Страница 5: ...Quantity Remark Fiber Laser module 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24VDC 1V power source 1 Caution Make sure the corresponding wires of the device are p...

Страница 6: ...y works continuously 1 4 Specifications Table 2 10Q 20QE 20Q 30Q 50QB pulsed fiber laser specifications Pulsed fiber laser 10Q 20QE 20Q 30Q 50QB Wavelength nm 1060 1085 1060 1085 1060 1085 1060 1085 1...

Страница 7: ...in Fig 1 Figure 1 Dimension drawing of laser module Unit mm 2 Isolated output head dimensions As shown in Fig 2 Figure 2 Dimension drawing of output isolator Unit mm 2 2 Method of installation 1 Fix...

Страница 8: ...ure that the interface of the external controller matches the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Fig 4 User s cont...

Страница 9: ...No Name Description 1 8 D0 D7 Power Setting 8 bit Parallel port D0 is minimum bit and D7 is maximum bit Range 0 255 hexadecimal 0X00 0XFF 0 is minimum power and 255 is maximum power 10 13 15 24 25 Gr...

Страница 10: ...N 4 0 0 0 0 1 PIN 5 0 0 0 1 1 PIN 6 0 0 1 1 1 PIN 7 0 1 1 1 1 PIN 8 1 1 1 1 1 Current 50 75 87 5 93 75 100 2 Alarms status Pins 11 12 16 and 21 are the alarm and status outputs Pin 12 is reserved alwa...

Страница 11: ...uide Ytterbium Pulsed Fiber Laser RFL P10Q P20Q P30Q P20QE P50QB Ver 2 0 7 9 5 PIN 22 is the guide laser red diode on off signal High level switch on the guide laser while low level switch off the gui...

Страница 12: ...ng range is from 30 KHz to 60 KHz For model P50QB the frequency setting range is from 50 KHz to 100 KHz 3 Laser marking checking For the device initial testing first turn the power down to zero withou...

Страница 13: ...ue to excessive use or not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device Any damage cau...

Отзывы: