Raycus RFL-C1500 Скачать руководство пользователя страница 1

Лазерны

й

 источник 

RAYCUS RFL-C

1 5

0

0

H

Содержание RFL-C1500

Страница 1: ...Лазерный источник RAYCUS RFL C1500H ...

Страница 2: ... Attentions 11 2 7 Specifications 12 3 Installation 12 3 1 Dimensions 13 3 1 1 Overall dimensions of RFL C1500 cutting laser 13 3 2 Size and installation of output optical cable 14 3 2 1 RFL C1500 Output Optical Cable 14 3 3 Cooling system installation and requirements 15 3 4 Installation rules 17 4 Using the Product 19 4 1 Front panel 19 4 2 Rear Panel 19 4 3 Power Connection 21 4 4 Interface def...

Страница 3: ...nect 4 6 in sequence 31 4 7 3 External control mode sequentially connected to 4 6 32 4 7 4 AD Mode 33 4 7 5 Controlling time series chart 35 4 7 6 Red Light Control 35 4 8Turning off the laser 36 5 Common Alarms and solutions 37 5 1 Alarm display 37 5 2 Alarm processing 37 6 Warranty Return and Maintenance 41 6 1 General Warranty 41 6 2 Limitations of Warranty 41 6 3 Service and Repair 42 ...

Страница 4: ...al injury or death CAUTION Describes a hazard that leads to a minor personal injury or product damage 1 2 Laser Safety Grade This series of lasers are classified as a high power Class 4 laser instrument accounting to the European community standards EN 60825 1 clause 9 This product emits invisible laser radiation at wavelength of 1080 nm and the light power is 100 2000W depending on the model Unde...

Страница 5: ...re range of laser wavelengths Please do not directly look at the fiber delivery cable connector when laser is powered on 1 3 Security Identifiers Raycus CW Fiber Lasers have different locations of safety identifier depending on the model as shown in Figure 1 Figure 1 Laser Security Identifiers Laser safety identifiers include safety warning laser output head warning product certification ID label ...

Страница 6: ... the end of the collimator assembly can burn the lens CAUTION DO NOT emit laser when the protective cap is not removed otherwise the lens or crystal will be damaged 1 5 Electrical Safety 1 Make sure the product is firmly grounded through the PE line of the AC power cord WARNING Any interruption from the protective earth will electrify the enclosure which may result in personal injury for operators...

Страница 7: ...onment 3 If this device is used in a manner not specified in this document the protection provided by the device may be impaired and the warranty will be voided 4 There are no user serviceable parts equipment or assemblies inside the product All service and maintenance shall be performed by Raycus In order to prevent electric shock please do not break the seal or uncover the shield Failure to comp...

Страница 8: ...nti reflection Capacity High modulation frequency and editable waveform Applications Welding 5G Infrastructure 3D printing Laser research 2 2 Model description Raycus continuous wave laser includes 100 200L 200 300L 300 500 750 1000 and other models which respectively represent 100W 170W 200W 250W 300W 500W 750W 1000W and 1500W lasers The definitions of the model code are shown in the table below ...

Страница 9: ...ximal safety Nevertheless in order to prevent the occurrence of unpredictable circumstances during the transportation please inspect all packaging once receiving the delivery If you find any evidence of mishandling or damages please keep the damaged material and contact the shipping agent and Raycus immediately Please double check if each listed content is included inside the package and contact R...

Страница 10: ...pacity kW 5 5 Installation Environment Flat and no vibration Ambient Temperature 10 40 Relative Humidity 70 Warning 1 Make sure the product is properly grounded before use 2 The laser output head is connected with fiber optic cable Please inspect the output head carefully to prevent dust or other contaminations Use appropriate lens paper to clean it if necessary 3 Failure to follow the instruction...

Страница 11: ...21 23 24 30 4 6 10 5 15 18 5 21 5 24 26 28 29 35 8 5 15 19 5 23 26 28 5 31 33 34 40 13 20 24 27 5 31 33 5 36 38 39 Laser operating temperature range 2 6 Attentions 1 Make sure that the correct voltage according to Table 3 is used before connecting AC current Failure to connect power supply will damage the device 2 Failure to operate the laser in accordance with the control or adjustment methods sp...

Страница 12: ...entTemp 25 ModulationFrequency Hz 50 20 000 NominalOutputPower RedGuideLaserPower mW 0 1 1 OpticalOutputCharacteristicsofQBHhead BeamQuality M NominalOutputPower CoreFiber μm 50 14 20 100 200 are optional DeliveryCableLength m 20 ElectricalCharacteristics PowerSupply 220 10 VAC 50 60Hz 5500 Max Power Consumption W ControlMode RS 232 AD Ethernet OtherCharacteristics Dimensions W H D 410 610 150 inc...

Страница 13: ...er 3 Installation 3 1 Dimensions 3 1 1 Overall dimensions of RFL C1500 cutting laser The front and rear panel sizes of the small volume 1500W continuous laser are same as the RFL C1000 laser as show in Figure 2 Figure 2 a Front view Unit mm Figure 2 b Rear view unit mm 13 ...

Страница 14: ...46 in the chart 3 2 Size and installation of output optical cable Raycus continuous wave fiber laser uses different laser output cables according to different laser models 3 2 1 RFL C1500 Output Optical Cable The output cables of Raycus RFL C1500 cutting fiber lasers are self made IQB output cables The specific appearance dimensions are shown in Figure 4 below 14 ...

Страница 15: ...ter the output fiber cable is installed in the processing equipment Before installing the output cable in the processing head the lens of the output cable must be inspected If the lens is dirty it must be cleaned It is forbidden to disassemble the output lens by anyone other than Raycus otherwise the warranty will be invalid 3 3 Cooling system installation and requirements Table 6 Cooling System R...

Страница 16: ... it every 2 months If ambient temperature is below 10 the chiller with both heating and cooling functions must be used and keep it in full time operation 3 Other cooling system requirements Check the entire water system and joints for leaks when starting the cooling system the first time The external water pipe must be installed and connected according to the water inlet IN and water outlet OUT in...

Страница 17: ...n immobilize it if necessary 2 Check if the power supply has the correct voltage laser model and power voltage refers to product parameters in Table 5 and the earth line is connected and ensure the earth line is firmly connected 3 Connect the power cable and control cable to the product when power supply is OFF 4 Connect the cooling system to the laser and output fiber cables according to the wate...

Страница 18: ...state such as transport and storage The minimum bending diameter should not be less than 30cm when the laser is working CAUTION All the cables can only be connected when power supply is off Hot plug may damage the device Ensure that there are no fiber bends in radius less than 30cm when the product is installed Avoid excessive twisting and tight bends during the robotic arm movements Tight bends w...

Страница 19: ...ficial website of Raycus to download the new version of the upper computer software and upper computer software instruction manual Web http www raycuslaser com index php index show tid 53 html 4 1 Front panel Figure 5 shows the front panel style of RFL C1000 RFL C1500 welding laser taking RFL C1000 as an example the front panel styles of other products are the same Figure 5 RFL C1000 laser front p...

Страница 20: ...ert the quick plug water pipe with an outer diameter of 16 into the pagoda head and fasten it with a clamp to connect the laser to the circulating cooling water 5 Interface Laser external control interface see 4 4 Interface and Definition 6 RS232 232 serial interface for communication between laser and host computer 7 ETHERNET Ethernet interface for communication between laser and upper computer 8...

Страница 21: ... RFL C1500 Power supply 220 10 V AC 50 60Hz Power cord Power cord end Three strands marked L N and PE respectively Label description L Phase line brown N Neutral blue PE Protective earth wire yellow green Note Insert the plug at the end of the power cord into the socket marked AC INPUT on the rear panel Note that the plug has anti reverse connection function After plugging it in lock it with a loc...

Страница 22: ...ent 2 Reserve interlock Short circuit 3 Reserve interlock 8 Reserve long dista nce power supply Short circuit 9 Reserve long dista nce power supply 10 Reserve emergency stop Short circuit 12 Analog Analog input External analog quantity setting 0 10V 0V 0 10V 100 10mA 13 Laser Power Analog output Optical power signal output 0V 0 3 3V 100 10mA 14 AGND Analog ground 12 13 pin return 0V 15 MOD Digital...

Страница 23: ...V 10mA 22 Laser Error Digital output Laser fault output signal EVCC 100mA 23 EVCC Digital input External voltage for output of Ready and Error signals 5 24V 5V 24V 100mA other NC Not allowed to connect Please check the level of the control signal to ensure compliance Exceeding voltage or voltage fluctuations may damage the laser Please ensure that the analog signal DOES NOT exceed 10V or product m...

Страница 24: ...d For specific commands and descriptions please refer to the software manual of the host computer or ask a Raycus technician for a communication protocol The specific parameter settings of the RS 232 control interface are as follows Table 10 RS 232 interface configuration parameters Parameters Set up Baud rate 9 600 Data bits 8 Stop bit 1 polarity None Flow control None Figure 9 RS 232 serial cabl...

Страница 25: ...on The laser listens for connections on port 8099 The command must be sent as a single string in a single packet Table 11 Ethernet interface pin definition PIN Feature Description 1 TX Transmit Data 2 TX Transmit Data 3 RX Receive Data 4 N C Not Connected 5 N C Not Connected 6 RX Receive Data 7 N C Not Connected 8 N C Not Connected If conditions permit please use this interface first to get better...

Страница 26: ...ftware of Raycus to control the laser you need to find the folder where the upper computer software is located open the laser configuration file config xml and write the newly set IP address of the laser if you do not use the upper computer of Raycus please directly enter the fourth step Fourth Step Configure the Ethernet network connection on the PC side select Use the following IP address and ma...

Страница 27: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of 1500W CW laser 27 ...

Страница 28: ...e position to fix it with screws 2 Remove the protection cap of the output head use strong light to check if there is dust on the lens of the output end If so please clean it before use and then cover the protection cap of the output head 3 Install the output optical cable on the processing equipment according to the actual situation also install the output head cooling water pipe pay attention to...

Страница 29: ... the rocker switch is off All electrical connections must be completed before the laser is powered on 1 Turn on the chiller and check the water pipe for leaks If there is no leakage turn off the chiller and wait for the laser to turn on 2 Close the rocker switch on the rear panel and wait for the laser to power on and perform a self test Note When the working environment temperature and relative h...

Страница 30: ...ring diagram Figure 11 Wiring diagram in RS 232 mode Note In the above mode the upper computer of Raycus should be used to modify the mode turn off the external red light control external light out enable and external AD and only keep the modulation mode Laser Control card AC input regulator RS232 or Ethernet Connector 30 ...

Страница 31: ...uit initialization is completed 3 Turn off all external control mode of the laser turn off external control of red laser external light emitting enable external AD and modulation mode 4 Set the power of the laser the laser power is to be set by 0 10V analog quantity when the AD mode is on and to be set by the serial port or Ethernet when the AD mode is off 5 Turn on the laser enable Laser AC input...

Страница 32: ...ntrolled by the modulation signal provided by the user from the external MOD interface For the timing diagram see 4 7 5 Control timing Figure Gate mode When the duty cycle of the laser s internal frequency is set to less than 100 the laser works in internal modulation mode The laser is turned on and off by the user from the external MOD signal and internal frequency generator Stop internal pulse g...

Страница 33: ...face to issue the shutter open command enable light 9 The On Off of the laser is controlled by the modulation signal provided by the external mod interface Shutdown the laser please refer to 4 8 4 7 4 AD Mode The laser enters the external AD mode through the upper computer selection The laser power is controlled by the voltage between pin12 14 of DB25 control interface 0v 0 power 10v 100 power If ...

Страница 34: ...aycus Fiber Laser Technologies Co Ltd User Guide of 1500W CW laser 4 7 5 Controlling time series chart Figure 13 Standalone mode Continuous sequence diagram Figure 14 Standalone mode Pluse sequence diagram 34 ...

Страница 35: ... 7 6 Red Light Control Turn on the rocker switch the green POWER indicator light is on wait for 20s the laser enters the red light external control mode and a high level of 5 24V is given before the 17 20 pin If red light internal control is selected on the host computer you can use the host computer to click red light on to turn on the red light 35 ...

Страница 36: ...the laser Please turn off the laser in the following sequence 1 Turn off the laser output enable 2 Turn off the rocker switch 3 Turn off the chiller 4 If the laser is not equipped with air conditioner please ignore this step If it is equipped please wait for the air conditioner to continue working for 10min 5 Put on the output head protection cap 36 ...

Страница 37: ...ient software interface as shown in Figure 17 The laser will give an alarm in the case of abnormal internal temperature abnormal output power abnormal power supply abnormal condensation etc Figure 17 main interface of upper computer software When the laser is working and any alarm occurs except for the abnormal interlock the upper computer software interface will also display the alarm At the same...

Страница 38: ... panel of the laser has been pressed before powering on Solutions When this alarm occurs please power off the laser and make the light enable button pop up and then power on the laser again to cancel the alarm If the alarm continues to occur please contact Raycus Inter Lock Alarm Instruction Occurs when the laser InterLock is disconnected Solutions Short the InterLock pins If this error continues ...

Страница 39: ...the laser is emitting light Solutions Restart the Device If this error continues to occur please contact Raycus ACDC1 Alarm Instruction AC DC1 Alarm Laser power supply out of work or sudden power disconnect of the power supply system may cause the alarm Solutions Check whether the input AC voltage is normal Restart the laser to try when it is normal If the alarm continues to occur please contact R...

Страница 40: ...actual water temperature of the water is too low In addition a low ambient temperature may also cause a low temperature alarm when the laser is cold Please wait until the water temperature of the water rises above 10 C and then restrate the divice If the alarm continues please contact Raycus Hum Alarm Instruction The laser detects that the current temperature of the water cooled plate is lower tha...

Страница 41: ...e under warranty Raycus reserves the right to issue a credit note for any defective products produced in normal conditions 6 2 Limitations of Warranty The warranty does not cover the maintenance or reimbursement of our product of which the problem results from tampering disassembling misuse accident modification unsuitable physical or operating environment improper maintenance damages due to exces...

Страница 42: ...ycus personnel Please contact Raycus as soon as possible when problems under warranty about maintenance happened to the product The product returned with permission should be placed in a suitable container If any damage happened to the product please notify the carrier in document immediately We reserve the right to make changes in design or constructions of any of our products at any time without...

Страница 43: ...т Пт Сб Вс www purelogic ru 7 495 505 63 74 Москва 7 473 204 51 56 Воронеж 394033 Россия г Воронеж Ленинский пр т 160 офис 149 info purelogic ru 8 800 555 63 74 бесплатные звонки по РФ 800 1700 800 1600 выходной ...