Wuhan Raycus Fiber Laser Technologies Co., Ltd
U
ser Guide of 1000W CW laser
Raycus User Guide | Product Description
8
5
)
Do not look into the output head directly. Wear appropriate protective eye
glasses all the time when operating the laser
Do not expose this product to high humidity (humidity>
95%).
Do not allow this product to operate at a temperature
below the ambient dew point. (As shown in Table 4)
Table 4 Comparison table of constant dew point at ambient temperature and
relative humidity
Constant dew point table at ambient temperature and relative humidity
Ambient
temperature
(℃)
Maximum relative humidity
20%
30%
40%
50%
60%
70% 80% 90% 95%
20
-3.5
2
6
9
12
14.5
16.5
18
19
25
0.5
6
10.5
14
16.5
19
21
23
24
30
4.6
10.5
15
18.5
21.5
24
26
28
29
35
8.5
15
19.5
23
26
28.5
31
33
34
40
13
20
24
27.5
31
33.5
36
38
39
Laser operating temperature range
2.6 Attentions
1) Make sure that the correct voltage (according to Table 3) is used before
connecting AC current. Failure to connect power supply will damage the
device.
2) Failure to operate the laser in accordance with the control or adjustment
methods specified in this manual may cause damage.