Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
43
f) Wait for the laser tricolor light to turn on green and the laser preparation is completed.
g) Set the waveform number for pre-execution (program number is greater than 0).
h) Start the waveform on the rising edge of the external MOD signal.
I) Check that the red light of the laser tricolor lamp is on, and the laser is outputting light.
Note: high level time of MOD must be more than program operation; if MOD gives the falling
edge in advance, the computer software will show that the laser program is stopped abnormally.
6.5 Set the power analog as emission external control on the REM mode
Figure 23 Wiring diagram of setting the power analog as emission external control on the REM
mode.