QuickStat-TC
Installation & Operation Manual
A F
2
General Information
Use of this Manual
This manual covers the installation and operation of the Raychem
QuickStat-TC thermostat and must be used with the following document:
•
QuickNet System Installation Manual
(H57704)
Important:
For the Tyco Thermal Controls warranty and agency
approvals to apply, the instructions included in this manual and product
packages must be followed.
Features
The QuickStat-TC is an electronic thermostat that must be used with the
Raychem QuickNet floor heating mats.
QuickStat-TC provides the following features:
• Integrated Class A, Ground-Fault Circuit Interrupter (GFCI).
• Operates at 120 V, 208 V, 240 V, 60 Hz.
• Switches on your heating system at predetermined times on different
days of the week.
• Offers 4 periods each day that you can set at different temperatures.
• Comes with a preprogrammed schedule that is suitable for most
installations. However, you can customize this program any time you
wish.
• Allows you to reset the thermostat to factory settings.
• Changes the start time of a heating period automatically so that the
desired temperature is reached at the time that you set.
• Multiple temperature control options so users can control the system
based on floor temperature (F), ambient air temperature (A), or both
(AF).
• On/Off switch to turn off thermostat during summer months.
Specifications
Approvals
Technical Data
Supply voltage
120 V, 208 V, 240 V, 60 Hz
Maximum switching current 15 A
GFCI
Class A, 5 mA trip level
Ambient setpoint range
40°F to 86°F (5°C to 30°C)
(A/AF mode)
Floor setpoint range (F mode) 40°F to 104°F (5°C to 40°C)
Floor limit setpoint range
40°F to 104°F (5°C to 40°C)
(AF mode)
Operating temperature range 32°F to 120°F (0°C to 50°C)
Storage temperature range
–4°F to 120°F (–20°C to 50°C)
A
C
B
E
D
Kit Contents
A
1
QuickStat-TC thermostat
B
2
Mounting screws
C
1
Floor temperature sensor 15 ft (4.6m)
D
5
Wire nuts
E
1
Screwdriver
400-115-052