background image

QuickStat-TC

Installation & Operation Manual

A F

2

General Information

Use of this Manual

This manual covers the installation and operation of the Raychem

 

QuickStat-TC  thermostat and must be used with the following document: 

• 

QuickNet System Installation Manual

 (H57704)

 Important:

 For the Tyco Thermal Controls warranty and agency 

approvals to apply, the instructions included in this manual and product 

packages must be followed.

Features

The QuickStat-TC is an electronic thermostat that must be used with the 

Raychem QuickNet floor heating mats. 

QuickStat-TC provides the following features:

•  Integrated Class A, Ground-Fault Circuit Interrupter (GFCI).

•  Operates at 120 V, 208 V, 240 V, 60 Hz.

•  Switches on your heating system at predetermined times on different 

days of the week.

•  Offers 4 periods each day that you can set at different temperatures.

•  Comes with a preprogrammed schedule that is suitable for most 

installations. However, you can customize this program any time you 

wish.

•  Allows you to reset the thermostat to factory settings.

•  Changes the start time of a heating period automatically so that the 

desired temperature is reached at the time that you set.

•  Multiple temperature control options so users can control the system 

based on floor temperature (F), ambient air temperature (A), or both 

(AF).

•  On/Off switch to turn off thermostat during summer months.

Specifications

Approvals

 

Technical Data

Supply voltage 

120 V, 208 V, 240 V, 60 Hz

Maximum switching current  15 A 
GFCI 

Class A, 5 mA trip level

Ambient setpoint range 

40°F to 86°F (5°C to 30°C)

 

(A/AF mode)
Floor setpoint range (F mode)  40°F to 104°F (5°C to 40°C)
Floor limit setpoint range 

40°F to 104°F (5°C to 40°C)

 

(AF mode)
Operating temperature range  32°F to 120°F (0°C to 50°C)
Storage temperature range 

–4°F to 120°F (–20°C to 50°C)

A

C

B

E

D

Kit Contents

QuickStat-TC thermostat

Mounting screws

Floor temperature sensor 15 ft (4.6m)

Wire nuts

Screwdriver

400-115-052

Содержание QuickStat-TC

Страница 1: ...ammed schedule that is suitable for most installations However you can customize this program any time you wish Allows you to reset the thermostat to factory settings Changes the start time of a heating period automatically so that the desired temperature is reached at the time that you set Multiple temperature control options so users can control the system based on floor temperature F ambient ai...

Страница 2: ... Secure the power base to the electrical junction box using the provided mounting screws 8 Verify the settings of the configuration switches on the back of the control module Default settings for the configuration switches are highlighted below Important If your system is installed underneath laminate or engineered wood flooring you MUST use AF mode with the default settings Note the factory defau...

Страница 3: ...ber Note This function is disabled default setting when the clock loses its setting To enable Daylight Savings Time 1 Press and hold the Day button for 3 seconds until DLS appears on the screen 2 Press the up down buttons to toggle between On enabled and Off disabled 3 Press the Day button The year setting is displayed 4 Use the up down buttons to set the current year 5 Press the Day button The mo...

Страница 4: ...tter meet their lifestyle To do so 1 Press Pgm to access the programming mode Period 1 will be displayed 2 Press Day to select the day to program for the selected period To select the entire week press and hold the Day button for 3 seconds until all days are selected 3 Press Hour and Min to set the start time of the selected period or press Clear if you want to skip the period is displayed Note If...

Страница 5: ... to Automatic or Manual To reset the QuickStat TC to factory default settings 3 Turn the thermostat to Off 4 Press the up button and switch the thermostat On 5 After the thermostat setup is completed release the up button Error Messages The measured temperature is below the thermostat s display range Heating is activated The measured temperature is above the thermostat s display range Heating is d...

Страница 6: ...no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product and in no case will Tyco Thermal Controls or its distributors be liable for any incidental indirect or consequential damages arising from the sale resale...