background image

10

Содержание Heatranger 345W

Страница 1: ...and central heating The thermostatically controlled hot water boiler can be operated independently of the cooker and will provide hot water for central heating and domestic use normal setting for winter usage whilst manually operated spinwheel control on the front of the ashpit door will provide heat for cooking and domestic hot water normal setting for summer usage The cooker boiler flueway dampe...

Страница 2: ...upply will reduce its intensity If there is a damper in the chimney connector plug or close the opening 4 If a fire extinguisher is available open the appliance door just enough to insert the nozzle of a 10lb dry chemical fire extinguisher rated for Class ABC fires Discharge the entire content of the fire extinguisher into the appliance and shut the door 5 If possible wet down the roof and other o...

Страница 3: ...sed cooking Close and lock firebox door Push flue chamber damper back to position which has been found to give desired burning rate All fuels Using a Gas Poker a Check flue pipe is free of blockage b Open firebox door c Open ashpit door d De ash Fig 8 and remove clinker door Fig 10 Insert flat bayonet type gas poker on top of bottomgrate bars e Remove ashpan and empty Fig 9 f Open flue chamber dam...

Страница 4: ...TEMPERATURE BY DIRECTING THE HEAT TO WATER Cooking Only Set the spinwheel open The precise amount will be shown by experience with the appliance 2 3 turns will do to start After setting the cooker boiler damper knob to C set the flue chamber damper fully open after refuelling and reset to position which has been found by practical experience to give the best results Do not try to obtain a fast inc...

Страница 5: ...m and minimise burning rates NOTE THE PRECISE AMOUNT OF OPENING DEPENDS ON THE CHIMNEY DRAUGHT AND THE TYPE CONDITION OF WOOD TO BE BURNT THIS MAY TAKE 2 OR 3 DAYS TO ASCERTAIN 1 If the fuel in the firebox is exhausted prematurely the overnight chimney draught must be reduced by increasing the opening setting of the flue chamber door using the flue dilution lever 2 If the fuel does not burn but di...

Страница 6: ... that required close the spinwheel to approximately one turn open Thereafter control the temperature of the oven by adjusting the spinwheel NOTE THE METHOD SHOULD PROVE SUCCESSFUL IN ALMOST ALL CASES BUT IF CLOSING THE FLUE CHAMBER DAMPER CAUSES THE FIRE TO SMOKE IT SHOULD BE OPENED GRADUALLY UNTIL THE SMOKING STOPS To reduce top heat in the oven adjust the cooker boiler damper knob gradually away...

Страница 7: ...essary This should not be done whilst the cooker is hot DO NOT USE ABRASIVE PADS OVEN CLEANER OR CLEANERS CONTAINING CITRIC ACID ON ENAMELLED SURFACES IMPORTANT NOTE Aga recommend Vitreous Enamel Association approved cleaners for cleaning the vitreous enamelled surfaces of this product But they are unsuitable for use on chrome and stainless steel components including the hand rails and their brack...

Страница 8: ...ats the inner walls of the chimney Properly installed and operated this cooker will not emit fumes Occasional fumes from de ashing and re fuelling may occur but persistent fume emission must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate room b Let the fire out or remove lit fuel from cooker c Check for flue ...

Страница 9: ...9 ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...policy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described at any time Manufactured by Aga Station Road Ketley Telford Shropshire TF1 5AQ England www aga web co uk www agacookshop co uk www agalinks com ...