background image

Consumer Protection Act 1987

As responsible manufacturers, we take care to make sure that our
products are designed and constructed to meet the required safety
standards when properly installed and used.

IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING
WARRANTY:

Any alteration that is not approved by Aga, could

invalidate the approval of the appliance, operation of the warranty
and could also affect your statutory rights. Use only authorised
replacement parts.

All local regulations including those referring to national and
European standards need to be complied with when installing
the appliance.

Control of Substances - Health and Safety
Important

This appliance may contain some of the materials that are indicated.
It is the Users/Installers responsibility to ensure that the necessary 

personal protective clothing is worn when handling, where
applicable, the pertinent parts that contain any of the listed materials
that could be interpreted as being injurious to health and safety, see
below for information.

Firebricks, Fuel beds, Fuels

- when handling use disposable

gloves.

Fire Cement

- when handling use disposable gloves.

Glues and Sealants

- exercise caution - if these are still in liquid

form use face mask and disposable gloves.

Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil

- may be harmful if inhaled, may be irritating to skin,

eyes, nose and throat. When handling avoid inhaling and contact
with skin or eyes. Use disposable gloves, face-masks and eye
protection. After handling wash hands and other exposed parts.
When disposing of the product, reduce dust with water spray,
ensure that parts are securely wrapped.

The Rayburn 345W has been designed to burn a variety
of wood logs and thereby provide heating facilities for
cooking, domestic hot water and central heating.
The thermostatically controlled hot water boiler can be
operated independently of the cooker and will provide hot
water for central heating and domestic use (normal
setting for winter usage), whilst manually operated
spinwheel control on the front of the ashpit door will
provide heat for cooking and domestic hot water (normal
setting for summer usage).
The cooker/boiler flueway damper knob on the centre
front of the cooker below the top plate requires to be set
in conjunction with the flue chamber damper to obtain the
appropriate service required from the appliance.

FIREBRICK POSITIONS

The Rayburn 345W is delivered complete including a set
of boiler removable firebricks where positional location
determines the amount of hot water supplied in winter
and summer seasons.
The oven side and firebox front firebricks are
permanently fixed with fire cement and should remain in
their positions at all times.
The two boiler face side bricks and boiler face rear brick
are so located for summer use when hot water, for
domestic use only, will be provided.
For winter use or central heating facilities the boiler face
rear brick is removed and the two boiler face side bricks
are transferred to locate on/over the oven side bricks.

Secondary Air Slide.

On opening the firedoor the secondary air slide is seen
on the base of the opening and should be set according 

to the heating requirement. (See Fig. 6).
Air Slide Open - heating
Air Slide Closed - cooking

WARNING: HOT SURFACES, use the tool supplied to
operate this appliance. It is recommended to use the
heatproof glove supplied when raising the dome lids to
use the hotplate. Replacement gloves can be obtained
from the Aga Shop.

Users Instructions.
Rayburn Heatranger 345W
Wood Burning Cooker

INTRODUCTION

PREPARING COOKER FOR USE 

1

10/07 EOPI 515158

WARNING

THE ASHPIT AND FIREBOX DOORS MUST BE LOCKED

CLOSED AT ALL TIMES DURING NORMAL USE, EXCEPT

WHEN LIGHTING OR RE-FUELLING.

Fig. 1

[email protected]

Содержание Heatranger 345W

Страница 1: ...and central heating The thermostatically controlled hot water boiler can be operated independently of the cooker and will provide hot water for central heating and domestic use normal setting for winter usage whilst manually operated spinwheel control on the front of the ashpit door will provide heat for cooking and domestic hot water normal setting for summer usage The cooker boiler flueway dampe...

Страница 2: ...upply will reduce its intensity If there is a damper in the chimney connector plug or close the opening 4 If a fire extinguisher is available open the appliance door just enough to insert the nozzle of a 10lb dry chemical fire extinguisher rated for Class ABC fires Discharge the entire content of the fire extinguisher into the appliance and shut the door 5 If possible wet down the roof and other o...

Страница 3: ...sed cooking Close and lock firebox door Push flue chamber damper back to position which has been found to give desired burning rate All fuels Using a Gas Poker a Check flue pipe is free of blockage b Open firebox door c Open ashpit door d De ash Fig 8 and remove clinker door Fig 10 Insert flat bayonet type gas poker on top of bottomgrate bars e Remove ashpan and empty Fig 9 f Open flue chamber dam...

Страница 4: ...TEMPERATURE BY DIRECTING THE HEAT TO WATER Cooking Only Set the spinwheel open The precise amount will be shown by experience with the appliance 2 3 turns will do to start After setting the cooker boiler damper knob to C set the flue chamber damper fully open after refuelling and reset to position which has been found by practical experience to give the best results Do not try to obtain a fast inc...

Страница 5: ...m and minimise burning rates NOTE THE PRECISE AMOUNT OF OPENING DEPENDS ON THE CHIMNEY DRAUGHT AND THE TYPE CONDITION OF WOOD TO BE BURNT THIS MAY TAKE 2 OR 3 DAYS TO ASCERTAIN 1 If the fuel in the firebox is exhausted prematurely the overnight chimney draught must be reduced by increasing the opening setting of the flue chamber door using the flue dilution lever 2 If the fuel does not burn but di...

Страница 6: ... that required close the spinwheel to approximately one turn open Thereafter control the temperature of the oven by adjusting the spinwheel NOTE THE METHOD SHOULD PROVE SUCCESSFUL IN ALMOST ALL CASES BUT IF CLOSING THE FLUE CHAMBER DAMPER CAUSES THE FIRE TO SMOKE IT SHOULD BE OPENED GRADUALLY UNTIL THE SMOKING STOPS To reduce top heat in the oven adjust the cooker boiler damper knob gradually away...

Страница 7: ...essary This should not be done whilst the cooker is hot DO NOT USE ABRASIVE PADS OVEN CLEANER OR CLEANERS CONTAINING CITRIC ACID ON ENAMELLED SURFACES IMPORTANT NOTE Aga recommend Vitreous Enamel Association approved cleaners for cleaning the vitreous enamelled surfaces of this product But they are unsuitable for use on chrome and stainless steel components including the hand rails and their brack...

Страница 8: ...ats the inner walls of the chimney Properly installed and operated this cooker will not emit fumes Occasional fumes from de ashing and re fuelling may occur but persistent fume emission must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate room b Let the fire out or remove lit fuel from cooker c Check for flue ...

Страница 9: ...9 ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...policy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described at any time Manufactured by Aga Station Road Ketley Telford Shropshire TF1 5AQ England www aga web co uk www agacookshop co uk www agalinks com ...

Отзывы: