Provision must be made for additional ventilation. A
permanent unobstructed air vent having a minimum
effective area of 22cm
2
must communicate to outside air
or an adjacent room which in turn has a permanent vent
of at least the same size to outside air.
If a flue draught stabiliser is fitted in the flue this vent size
must be increased to a minimum 49cm
2
. If this appliance
is used with an additional appliance of a similar type then
the air supply must be adequate for both appliances in
accordance with Building Regulations.
Any air inlet grilles must be maintained so that they are
free from blockage.
OVEN DOOR OPERATION - SEE FIG. 1
To open the doors. Twist the handle slightly to lift up the
door catch from the locking spindle and pull the door
open.
To close the doors. Gently push the door shut until the
door catch makes contact with the locking spindle.
FIRE DOOR OPERATION - SEE FIG. 2
To open the door. Lift the door by the handle and pull
forward.
To close the door. Lift the door up by the handle and push
to shut.
THE FIREDOOR MUST BE LIFTED SLIGHTLY WHEN
OPENING AND CLOSING, OTHERWISE DAMAGE TO
THE DOOR CATCH WILL OCCUR.
DO NOT SLAM THE FIREDOOR SHUT!
DOOR OPERATION
DESN 512979
DESN 512978
2
Fig. 1
Fig. 2