Servicing or Fault
BURNER RESET
If a fault occurs on the burner then it automatically shuts
down and the red button on the front plinth will be illuminated.
This can be reset, after 10 seconds by depressing the reset
button. The reset button is located in the lower plinth panel.
OPERATING BY PRESSING WITH FINGER ONLY
Please wait at least 10 seconds between resetting the
lockout button. If resetting the lockout button does not light
the burner immediately, it will be necessary to repeat the
sequence.
Continued lockouts indicate a burner or gas supply
malfunction. This fault should be diagnosed and rectified.
In the event of repeated failure switch off the gas and
electrical supply to the appliance and contact your
installer/service engineer.
FLUE SAFETY DEVICE
For safety purposes a flue safety device is fitted. This will
only operate under adverse flue conditions, If the switch has
operated, it should be pushed into reset and the pilot re-lit. If
this problem persists contact your local engineer to
determine and rectify the cause. It is important not to reset
more than once as this may indicate a flue blockage.
GAS LEAK OR FAULT
If a gas leak or fault exists or is suspected the unit must be
isolated from the gas and electrical supply. The appliance
must not be used until the fault has been rectified.
Advice/Help should be obtained from your Installer/Servicing
Company.
POWER FAILURE
In the event of a short term power failure the clock display
will disappear and then return on the power supply being
reinstated.
However if the power supply is interrupted for any length of
time the clock display will be lost. Follow procedure ‘
TO SET
TIME
’.
SERVICING
With normal use the cooker will need annual flueway
cleaning and burner maintenance which should be carried
out by a competent engineer who is Gas Safe Registered.
A HOT APPLIANCE CANNOT BE SERVICED.
The cooker thermostat knob should be turned OFF the night
preceding the day of the servicing so that the appliance will
have cooled down by the following morning.
Fig. 18
BURNER RESET
BUTTON
FLUE SAFETY
DEVICE