Version C16. February 2013
Raveon Technologies Corporation
Company Confidential
19
The default settings that the
RV-M7 GX
will revert to when the CONFIG button is
pressed are:
1. Serial port 9600 baud, 8 data bits 1 stop, no parity
2. Serial port flow control is off.
3. ATCT setting set to 60000 (60 second time-out)
4. Encryption KEYPHRASE is erased (if it was set to some KEYPHRASE and the user-
interface had password protection enabled)
Even though the serial baud rate reverts to 9600 baud when the CONFIG button is
pressed and the IO port is RS-232, it will revert back to the settings programmed
into the
RV-M7 GX
once the Command Mode is exited.
Important Note!
If the user-interface is password protected, AND the
Config
button
on the M7 is pressed, for security reasons, the encryption phrase is
automatically erased.
5.7.
Exiting the Command Mode
There are three ways to exit the command mode. They are:
1.
ATCN
Issuing the
ATCN
. The M7 radio will exit the command mode, and
begin normal operation.
2.
EXIT
Issuing the EXIT command. The M7 radio will exit the command mode,
and begin normal operation.
3.
Time Out
. After a pre-set amount of time (60 seconds is the factory default
time), the modem will automatically exit the Command Mode, and continue normal
operation. Changes will not automatically be saved. This time-out duration may be
set with the
ATCT
command.
5.8.
Restoring Factory Defaults
The
AT&F
command may be used to restore the modem back to the factory-
default condition. The table in Section 5.9 lists all of the radio modem related
commands. Use this command with caution, as it will erase all previously
configured parameters. It will cause the modem to revert back to the factory-
defaults, as shown in the command table, “Factory Default” column. The only