C
HAPTER
7
48
Viper/Viper 4+ Installation & Operation Manual
6. From the File Export screen, select either Slingshot or the listed USB drive. If more than one USB drive is
inserted there may will be multiple choices.
7. With at least one file selected, select one of the following export actions:
•Copy - create a duplicate of the selected information on the destination to be selected
•Move - export the selected information to the destination to be selected and remove the information
from the ROS device.
The Export Files prompt will display.
NOTE:
Refer to the ROS Slingshot Field Hub Calibration and Operation Manual for more information on
using the Slingshot Field Hub with ROS.
8. Send with Folder Structure
Select this option to export the field operation file types to the USB flash drive with the grower, farm, field (GFF)
file structure. The field operation files may be transferred to a Slingshot viewer or user account to review job
information, or to another ROS device via the USB flash drive to continue the job.
NOTE:
While the GFF file structure is transferred to the USB flash drive using this export option, the GFF
assignments will not be inherently associated with the field operation files if transferred to another
ROS device.
To reassociate the .jdp with the GFF information, import the GFF structure via the USB manager and
then reassign the .jdp to the GFF using the File Manager tab. Review the Import Grower, Farm Field
(GFF) Folder Structure section on page 50 for assistance with importing the GFF information and the
Grower, Farm, Field (GFF) Manager section on page 43 for details on using the file manager to
reassign the GFF associations.
Send as Slingshot Archive.
The Slingshot Archive (.ssa) file type may be used with either a Slingshot user account
or to transfer multiple files to another ROS device. Select this file type to transfer multiple files as one package.
NOTE:
If imported onto another ROS device, files exported as an .ssa will retain GFF associations from the
original device. All files exported to the “slingshotArchives” directory on the USB flash drive will be
required to retain the GFF associations from the previous device.
9. Touch the Confirm button on the Export to USB prompt to start the export process. When complete, the ROS
device will return to the File Export tab.
EXPORT ISO TASK DATA
1. Touch the Administrator or User Panel along the top of the Main Panel display to expand the panel.
Administrator
or User Panel
File
Manager
File Management Options
Содержание viper
Страница 1: ...Viper Viper 4 Installation Operation Manual Manual No 016 0171 539 Rev F 11 16 E27652 Copyright 2016 ...
Страница 16: ...CHAPTER 2 8 Viper Viper 4 Installation Operation Manual ...
Страница 48: ...CHAPTER 6 40 Viper Viper 4 Installation Operation Manual ...
Страница 67: ...File Manager 59 FILE MANAGER ...
Страница 68: ...CHAPTER 7 60 Viper Viper 4 Installation Operation Manual ...
Страница 112: ...CHAPTER 9 104 Viper Viper 4 Installation Operation Manual ...
Страница 174: ...CHAPTER 16 166 Viper Viper 4 Installation Operation Manual ...
Страница 176: ...CHAPTER 17 168 Viper Viper 4 Installation Operation Manual ...